2400W Single Output Power Supply
RSP-2400 series
Features :
AC input 180 ~ 264VAC
AC input active surge current limiting
High efficiency up to 91%
Built-in active PFC function,PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
/ Fan alarm
Forced air cooling by built-in DC with fan speed control function
Output voltage can be trimmed between 20~110% of the rated output voltage
High power density 12.5W/inch3
Current sharing up to 3 units
Alarm signal output (relay contact and TTL signal)
Built-in 12V/0.1A auxiliary output for remote control
Built-in remote ON-OFF control
Built-in remote sense function
3 years warranty
SPECIFICATION
MODEL
RSP-2400-12
RSP-2400-24
RSP-2400-48
DC VOLTAGE
RATED CURRENT
12V
24V
48V
166.7A
0 ~ 166.7A
2000.4W
100A
50A
CURRENT RANGE
RATED POWER
0 ~ 100A
2400W
150mVp-p
22 ~ 28V
1.0%
0 ~ 50A
2400W
200mVp-p
43 ~ 56V
1.0%
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 1.0%
OUTPUT
10.8 ~ 13.2V
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1000ms, 80ms at full load
12ms at full load
VOLTAGE RANGE
180 ~ 264VAC
47 ~ 63Hz
254 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
0.95/230VAC at full load
87%
INPUT
90%
91.5%
15.5A/180VAC
12A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
60A/230VAC
LEAKAGE CURRENT
<2.0mA / 240VAC
100 ~ 112% rated output power
OVERLOAD
User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 5 seconds, re-power on to recover
13.8 ~ 16.8V 28.8 ~ 33.6V 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
PROTECTION OVER VOLTAGE
95
95
5
5
(12V), 100
(12V), 85
5
(24V,48V) (TSW1: detect on heatsink of power transistor)
(24V), 80 (48V) (TSW2 : detect on heatsink of o/p diode)
5
5
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
12V@0.1A(Only for Remote ON/OFF control)
AUXILIARY POWER(AUX)
REMOTE ON/OFF CONTROL
ALARM SIGNAL OUTPUT
Please see the Function Manual
Please see the Function Manual
FUNCTION
2.4 ~ 13.2V
4.8 ~ 28V
9.6 ~ 56V
OUTPUT VOLTAGE TRIM
CURRENT SHARING
Please see the Function Manual
-20 ~ +70 (Refer to output load derating curve)
20~90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
TEMP. COEFFICIENT
VIBRATION
0.05%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22)
EMC
(Note 4)
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
106.7K hrs min. MIL-HDBK-217F (25
278*177.8*63.5mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
3.3Kg; 4pcs/14.2Kg/1.89CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:RSP-2400-SPEC 2010-10-18