1000W Single Output Power Supply
RSP-1000 series
Features :
Universal AC input / Full range
AC input active surge current limiting
Built-in 5V/0.5A auxiliary power
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Output voltage can be trimmed between 40 ~ 110% of the rated output voltage
Forced air cooling by built-in DC fan
High power density 10.7w/inch3
1U low profile 41mm
Active current sharing up to 4000W(3+1) (Note.8)
DC OK Signal
Built-in remote ON-OFF control
Built-in remote sense function
3 years warranty
..
SPECIFICATION
MODEL
RSP-1000-12
RSP-1000-15
RSP-1000-24
RSP-1000-27
RSP-1000-48
DC VOLTAGE
12V
15V
24V
27V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
60A
50A
40A
37A
21A
0 ~ 60A
720W
0 ~ 50A
750W
0 ~ 40A
960W
0 ~ 37A
999W
150mVp-p
24 ~ 30V
1.0%
0 ~ 21A
1008W
150mVp-p
43 ~ 55V
1.0%
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE 10 ~ 13.5V
VOLTAGE TOLERANCE Note.3 1.0%
150mVp-p
13.5 ~ 16.5V
1.0%
150mVp-p
20 ~ 26.4V
1.0%
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
300ms, 50ms at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
16ms/230VAC
16ms/115VAC at full load
127 ~ 370VDC
Note.5 90 ~ 264VAC
47 ~ 63Hz
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
0.95/230VAC
83%
0.98/115VAC at full load
85%
INPUT
88%
88%
90%
12A/115VAC
25A/115VAC
<2.0mA / 240VAC
6A/230VAC
40A/230VAC
105 ~ 125% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
13.8 ~ 16.8V 17 ~ 20.5V 27.6 ~ 32.4V 31 ~ 36.5V
Protection type : Shut down o/p voltage, re-power on to recover
85 (TSW2 ) detect on heatsink of O/P diode; 75 (TSW1 ) detect on heatsink of power transistor
OVERLOAD
56.6 ~ 66.2V
PROTECTION OVER VOLTAGE
5
5
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
5V @ 0.5A (+5%, -8%)
AUXILIARY POWER(AUX)
REMOTE ON/OFF CONTROL Note.6
DC OK SIGNAL
Power on : short between on/off(pin6) & -S(pin2) on CN50
Power off : open between on/off(pin6) & -S(pin2) on CN50
FUNCTION
The TTL signal out, PSU turn on = 0 ~ 1V ; PSU turn off = 3.3 ~ 5.6V
Adjustment of output voltage is possible between 40 ~ 110% of rated output
Please refer to function manual
OUTPUT VOLTAGE TRIM Note.6
CURRENT SHARING(CS)Note.7
WORKING TEMP.
-20 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
TEMP. COEFFICIENT
VIBRATION
0.02%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22)
EMC
(Note 4)
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
116.75K hrs min. MIL-HDBK-217F (25
295*127*41mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
1.95Kg; 6pcs/12.7Kg/0.99CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. The power supply unit will have no output if the shorting connector is not assembled. It contains two shorting wires: one is from on/off(pin6) to -s(pin2)
and the other is from Vco(pin8) to Vca(pin10). Please refter to function manual for details.
7. In parallel connection, maybe only one unit operate if the total output load is less than 5% of rated load condition.
8. Please consult MEAN WELL for applications of more units connecting in parallel.
File Name:RSP-1000-SPEC 2011-02-17