● Single Outputs up to 15A
● Input/Output 1.6kVDC Isolation
● Adjustable Output Voltage
● No Minimum Load
INNOLINE
Features
DC/DC-Converter
● Under -Voltage Lockout
● Industry Standard Footprint
● Fixed Operating Frequency
● Halt Tested
● Compact 61.0 x 57.91 x 12.7mm Package
● High Efficiency to 91%
RP50-S
Series
50 Watt
Single
Output
Selection Guide
Part
Number
Single Output
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Line
Load
Input Efficiency
Current Regulation Regulation Current
(A)
15
15
15
10
3.3
15
15
15
10
3.3
(mV)
4
(mV)
6
(A)
%
RP50-241.8S
RP50-242.5S
RP50-243.3S
RP50-2405S
RP50-2415S
RP50-481.8S
RP50-482.5S
RP50-483.3S
RP50-4805S
RP50-4815S
18 – 36
18 – 36
18 – 36
18 – 36
18 – 36
36 – 75
36 – 75
36 – 75
36 – 75
36 – 75
1.8
2.5
3.3
5
1.36
1.86
2.40
2.40
2.40
1.36
1.86
2.40
2.40
2.40
86
87
89
90
89
87
89
90
91
90
5
8
7
10
15
45
6
10
30
4
15
1.8
2.5
3.3
5
5
8
7
10
15
45
10
30
15
Notes:
1. Maximum output deviation is 10% inclusive of remote sense. If remote sense is not being used,
the +Vsense should be connected to its corresponding +Vout
2. Measured with a 1uF M/C and a 10µF T/C.
3. An external filter capacitor is required for normal operation. The capacitor should be capable of handing 1A
ripple current for 48V/24V models. RECOM suggests: Nippon chemi-con KMF series, 220µF/100V, ESR 90mΩ.
4. The negative/ positive logic and pin length are optional ( see table ). The pin voltage is referenced to
negative input.
5. Heat sink is optional and P/N: 7G-0021, 7G-0022, 7G-0023, 7G-0024.
6. The RP50 meets level A and level B conducted emissions only with external components connected before
the input pin to the converter.
7. Maximum value at nominal input voltage and full load.
8. Typical value at nominal input voltage and full load.
9. BASEPLATE GROUNDING : Base-plate should be grounded at one of the four screw bolts prior to operation.
10. The converter is provided by basic insulation.
11. “NN” for Negative remote ON/OFF.
12. “PP” for Positive remote ON/OFF.
July-2006
178