• Wide 4:1 input voltage range
• 1.6kVDC isolation for 24Vin and 48Vin,
3kVDC isolation for 110Vin
Features
DC/DC Converter
• Efficiency up to 92%
Regulated
Converter
• Six-sided continuous shield
• EN50155, UL/IEC/EN60950-1 certified
RP40-FR
40 Watt
2“ x 1“
Single and Dual
Output
Description
3
The RP40-FR series wide range input DC/DC converters have been especially designed for railway
applications and are EN50155 certified. They are also certified to UL60950-1 and cUL 60950-1, this
makes them ideal for all high input voltage telecom and industrial applications where approved safety
standards are required.
Selection Guide
Part Number
Input
Output
Output
Current
[mA]
Input (1) Efficiency (1) Max. Capacitive
Voltage Range Voltage
Current
[mA]
typ.
[%]
Load (2)
[µF]
[VDC]
9-36
9-36
9-36
9-36
[VDC]
3.3
5
12
15
24
3.3
5
12
15
24
3.3
5
12
15
24
12
15
24
12
15
24
12
15
24
RP40-243.3SFR (3,4)
RP40-2405SFR (3,4)
RP40-2412SFR (3,4)
RP40-2415SFR(3,4)
RP40-2424SFR (3,4)
RP40-483.3SFR (3,4)
RP40-4805SFR (3,4)
RP40-4812SFR (3,4)
RP40-4815SFR (3,4)
RP40-4824SFR (3,4)
RP40-1103.3SFR (3,4)
RP40-11005SFR (3,4)
RP40-11012SFR (3,4)
RP40-11015SFR (3,4)
RP40-11024SFR (3,4)
RP40-2412DFR (3,4)
RP40-2415DFR (3,4)
RP40-2424DFR (3,4)
RP40-4812DFR (3,4)
RP40-4815DFR (3,4)
RP40-4824DFR (3,4)
RP40-11012DFR (3,4)
RP40-11015DFR (3,4)
RP40-11024DFR (3,4)
10000
8000
3333
2666
1666
10000
8000
3333
2666
1666
10000
8000
3333
2666
1666
1666
1333
833
1528
1832
1811
1811
1831
764
916
906
906
915
90
91
92
92
91
90
91
92
92
91
88
89
90.5
91
90
90
90
91
90
90
91
89
89
91
26600
20000
3900
2600
1300
26600
20000
3900
2600
1300
26600
20000
3900
2600
1300
2600
1600
650
9-36
18-75
18-75
18-75
18-75
18-75
43-160
43-160
43-160
43-160
43-160
9-36
RoHS2
+
REACH
compliant
compliant
10 from 10
E196683
341
409
402
400
EN50155 certified
404
UL60950-1 certified
IEC/EN60950-1 certified
EN55032 compliant
EN55024 compliant
EN50121-3-2 compliant
1851
1851
1830
925
741
572
408
408
400
9-36
9-36
18-75
18-75
18-75
43-160
43-160
43-160
1666
1333
833
1666
1333
833
2600
1600
650
2600
1600
650
REF
Notes:
DESIGN
available
Note1: Maximum values at nominal input voltage and full load at +25°C ambient
Note2: Max. Cap load is tested at minimum input and constant resistive load
Model Numbering
https://recom-power.com/
rec-s-R-REF04-RIA12.html
RP40-__ __ _FR/_- _
(4)
“Package
”
nom. Input Voltage
(3)
“CTRL Logic
”
nom. Output Voltage
SURGE
PROTECTOR
available
Single or Dual
Notes:
Note3: standard part is with suffix “P” for positive logic (1=ON, 0=OFF)
or add suffix “N” instead for negative logic (0=ON, 1=OFF)
Note4: add suffix “-HC” for premounted Heat-sink with clips
Ordering Examples
RP40-2405SFR/P = 24V input, 5V output, single, positive Logic CTRL pin
RP40-4812DFR/N-HC = 48V input, 12V output, dual, negative Logic CTRL pin, Heat-sink premounted
https://recom-power.com/rec-s-
RSPxxx-168.html
www.recom-power.com
REV.: 8/2020
PD-1