RP/RPT
MAIN FEATURE
1. 1 Pole and 2-Poles versions available with high
switching current up to 30A.
2. Plug-in Terminal with Flanged Case is available
for customer’s various applications.
3. Both AC and DC coil available.
4. LED version available.
5. Touch Button and LED version available.
6. Comply with RoHS and REACH regulations.
CONTACT RATING
Load Type
RP-2P
RP-3P
RPT (No Common)
30A/28VDC
30A/120VAC
30A/240VAC
10A/600VAC
-
RPT-2P
20A/15VDC
13A/28VDC
25A/120VAC
25A/240VAC
5A/600VAC
RPT- 3P
20A/15VDC
13A/28VDC
20A/120VAC
15A/240VAC
-
10A 240VAC
10A 240VAC
13A 120VAC
13A 120VAC
Rated Load (Resistive)
13A 28VDC
13A 28VDC
-
-
-
-
1/2HP 240VAC 1/2HP 240VAC
1HP/120VAC
3/4HP/120VAC 1/2HP/120VAC
Contact Capacity
1/3HP 120VAC 1/3HP 120VAC 1 HP/200~600VAC 1HP/240/480/600VAC 1/2HP/208/240VAC
Rated Carrying Current
13A
AC 300V
DC 48V
13A
13A
AC 300V
DC 48V
13A
30A
AC 600V
DC 28V
30A
25A
AC 600V
DC 28V
25A
20A
AC 300V
DC 28V
20A
Max. Allowable Voltage
Max. Allowable Current
2,400VA
364W
2,400VA
364W
7,200VA
840W
6,000VA
364W
3,600VA
364W
Max. Allowable Power Force
Ag Alloy
DPST, DPDT
Ag Alloy
3PST, 3PDT
Ag Alloy
SPST, SPDT
Ag Alloy
DPST, DPDT
Ag Alloy
3PST, 3PDT
Contact Material
Contact Form
APPLICATION
Humidity Range.................... 45 85% RH.
Coil Temperature Rise......... 50°C Max.
Vending Machine, Cooking Appliances, Office Machine,
Domestic Appliances, Control Equipment, etc
Vibration:
Destruction
10 to 55 to 10 Hz,0.75 mm single
amplitude (1.5mm double amplitude)
......................
......................
PERFORMANCE (AT INITIAL VALUE)
Malfunction
Shock:
10 to 55 to 10 Hz,0.75 mm single
amplitude (1.5mm double amplitude)
Contact Resistance..............100 m Max.@1A,6VDC
Operate Time........................15 mSec. Max.
Release Time .......................10 mSec. Max.
Dielectric Strength:
Destruction ...................... 1,000 m/S2
...................... 100 m/S2
Malfunction
Life Expectancy:
Between Coil & Contact.......1,500VAC at 50/60 Hz
for one minute
Between Contacts ................1,000VAC at 50/60 Hz
for one minute
Surge Strength .....................1,500V (between Coil
& Contact 1.2x50μSec.)
Mechanical ....................... 107 Operations at No
Load condition
Electrical .......................... 105 Operations at Rated
Resistive Load
Weight ............................. About 85 g
Insulation Resistance...........100 Mega Min. at
500VDC
ACCESSORIES & SOCKETS
Max. On/Off Switching:
PPF-11A/AE .................... See Page 170
Electrical ...............................6 Cycles per Minute
Mechanical............................300 Cycles per Minute
Temperature Range.............-45 +70°C
SAFETY STANDARD & FILE NUMBER
RPT
UL & C-UL ....................... E175730
RP
NIL.
158