RHCA5039
RHCA5639 SERIES
SURGE PROTECTIVE DEVICES
RHCA5039 series is suitable for products that need
DC insulation resistance test on Line-FG, SG of a
communications / signal line. Impulse current
capacity is 2,000A 8/20μs.
Safety Standard
:UL1449 4th.
File No.
UL
cUL
:C22.2 No.8-13
E322107
UL-EU :EN61643-311
:IEC61643-311
Features
● Chip surge absorber for protection from indirect
lighting surge, adaptable to high density surface
mount technology
● Impulse current capacity 2,000A 8/20μs
● Small electrostatic capacity(Maximum 0.6pF)
● Impulse Absorption Characteristics
Impulse waveform 1.2/50μs-10,000V
Peak:10,000V
RHCA-242H53U
Impulse waveform
Breakdown
Voltage
1μs/div
1μs/div
3,240V
Electrical Specifications
●RHCA53 series
Safety
DC
Breakdown
Voltage
(V)
Withstanding
Voltage
50/60Hz
Insulation
Resistance
(MΩ) Min.
Capacitance
1MHz
(pF) Max.
Impulse
Current
Capacity
Impulse Sparkover Voltage
Standard
Impulse
Life Test
1.2/50ꢀs (V) max.
Applied Voltage Specification
4,500V max.
Model Number
UL1449
cUL
UL-EU
AC1,000V-60sec
AC1,200V-3sec
*1
RHCA-242H53U
RHCA-302H53U
RHCA-362H53U
2,400±20% *3
3,000±20% *3
3,600±20% *3
8/20μs
100A
300 times
8/20μs
*1
1,000(DC500V)
0.6
5,000V
*2
4,700V max. AC1,500V-60sec
2,000A
AC1,500V-60sec
4,950V max.
*1
*2
AC1,800V-3sec
●RHCA53(335) series
Safety
Standard
Impulse Sparkover Voltage
DC
Breakdown
Voltage
(V)
Withstanding
Voltage
50/60Hz
Insulation
Resistance
(MΩ) Min.
Capacitance
1MHz
(pF) Max.
Impulse
Current
Capacity
1.2/50ꢀs (V) max.
Impulse
Life Test
Model Number
UL1449
cUL
*1
Applied
Specification
Voltage
UL-EU
RHCA-102P53U(335)
RHCA-102Q53U(335)
RHCA-202H53U(335)
1,000±20%
1,000±30%
2,000±20% *3
*2
-
-
-
*1
*2
*1
AC1,000V 60s
AC1,000V 60s
AC1,200V 3s
AC1,200V 60s
*1
RHCA-242H53U(335)
4,500V max.
2,400±20% *3
8/20μs
100A
300 times
1,000(DC500V)
8/20μs
*1
0.6
RHCA-272H53U(335) 5,000V
RHCA-302H53U(335)
2,700±20% *3
3,000±20% *3
3,500A
*1
4,700V max. AC1,500V 60s
*2
AC1,500V 60s
4,950V max.
*1
RHCA-362H53U(335)
3,600±20% *3
*2
AC1,800V 3s
*1
RHCA-402H53U(335) 7,500V 7,450V max. AC2,000V 60s
RHCA-452H53U(335) 8,000V 7,950V max. AC2,000V 60s 1,000(DC1,000V)
4,000±20% *3
4,500±20% *3
*2
*1
*2
*1 Rated voltage AC125V: Approved if it is connected to UL approved varistor (V1.0mA≥270V, D≥φ 7mm).
*2 Rated voltage AC250V: Approved if it is connected to UL approved varistor (V1.0mA≥470V, D≥φ 7mm). *3 Reference Value
Operating Temperature: -20~+80°C
●The content may change without notice. Please refer to our specification sheet before ordering.
DAT.NO. 32005E001-2002