REVISION AF
RFXXX-XXXXX-XXXXXX-XXXX
DESIGNED & DIMENSIONED
IN MILLIMETERS[INCHES]
CABLE CALL OUT
OVERALL CABLE LENGTH
MILLIMETERS OF CABLE
0100 MIN. (SEE NOTE 8 & 9)
174: CCA-174 (RG-174 COAXIAL CABLE)
316: CCA-316 (RG-316 COAXIAL CABLE)
DO NOT
SCALE FROM
THIS PRINT
END 1 CONNECTOR
END 2 PLATING OPTION
-01SP: SMA-P-C-X-ST-CA1 (SEE SHEET 3)
-01RP: SMA-P-C-X-RA-CA1 (SEE SHEET 3)
-01BJ: SMA-J-C-X-ST-BH1 (SEE SHEET 3)
-01BR: SMA-J-C-X-ST-BR1 (SEE SHEET 3)
-02SJ: MCX-J-C-X-ST-CA1 (SEE SHEET 3)
-02RP: MCX-P-C-XX-RA-CA1 (SEE SHEET 3)
-02SP: MCX-P-C-XX-ST-CA1 (SEE SHEET 4)
-03SP: MMCX-P-C-XX-ST-CA1 (SEE SHEET 4)
-03RP: MMCX-P-C-X-RA-CA1 (SEE SHEET 4)
-04SP: BNC5-P-C-XX-ST-CA1 (SEE SHEET 4)
-04BJ: BNC5-J-C-XX-ST-BH1 (SEE SHEET 4)
-05SP: TNC-P-C-XX-ST-CA1 (SEE SHEET 4)
-05BJ: TNC-J-C-XX-ST-BH1 (SEE SHEET 5)
-06BJ: NTPE-J-C-XX-ST-BH1 (SEE SHEET 5)
-07SP: SMB5-P-C-XX-ST-CA1 (SEE SHEET 5)
-07RP: SMB5-P-C-XX-RA-CA1 (SEE SHEET 5)
-07BJ: SMB5-J-C-X-ST-BH1 (SEE SHEET 5)
-13GP: GRFS-P-C-X-ST-CA1
1: GOLD ALL COMPONENTS
2: GOLD / NICKEL COMBINATION
3: ALTERNATE GOLD / NICKEL
4: ALTERNATE GOLD / GOLD FLASH / NICKEL
7. ALTERNATE GOLD MEDIUM/ GOLD FLASH
(LEAVE BLANK FOR -SING OR -XXXXXX
END 2 PREPARATION)
FIG.2
CABLE STRIPPING DIMENSIONS
PER CONFIGURATIONS
(SEE TABLE 1)(SEE NOTES 12,13,14,15)
END 2 CONNECTOR OR PREPARATION
-01SP: SMA-P-C-X-ST-CA1 (SEE SHEET 3)
-01RP: SMA-P-C-X-RA-CA1 (SEE SHEET 3)
-01BJ: SMA-J-C-X-ST-BH1 (SEE SHEET 3)
-01BR: SMA-J-C-X-ST-BR1 (SEE SHEET 3)
-02SJ: MCX-J-C-X-ST-CA1 (SEE SHEET 3)
-02RP: MCX-P-C-XX-RA-CA1 (SEE SHEET 3)
-02SP: MCX-P-C-XX-ST-CA1 (SEE SHEET 4)
-03SP: MMCX-P-C-XX-ST-CA1 (SEE SHEET 4)
-03RP: MMCX-P-C-X-RA-CA1 (SEE SHEET 4)
-04SP: BNC5-P-C-XX-ST-CA1 (SEE SHEET 4)
-04BJ: BNC5-J-C-XX-ST-BH1 (SEE SHEET 4)
-05SP: TNC-P-C-XX-ST-CA1 (SEE SHEET 4)
-05BJ: TNC-J-C-XX-ST-BH1 (SEE SHEET 5)
-06BJ: NTPE-J-C-XX-ST-BH1 (SEE SHEET 5)
-07SP: SMB5-P-C-XX-ST-CA1 (SEE SHEET 5)
-07RP: SMB5-P-C-XX-RA-CA1 (SEE SHEET 5)
-07BJ: SMB5-J-C-X-ST-BH1 (SEE SHEET 5)
-13GP: GRFS-P-C-X-ST-CA1
"A" mm
"B" mm
"C" mm
C
C
"D" mm
"E" mm
(316 OPTION ONLY) (SEE SHEET 5)
C
-13GJ: GRFS-J-C-X-ST-CA1
(316 OPTION ONLY) (SEE SHEET 6)
-01SB: SMA-J-C-X-ST-SB1 (SEE SHEET 6)
-01SR: SMA-J-C-X-ST-SR1 (SEE SHEET 6)
-01PN: SMA-J-C4-XX-ST-PN1 (SEE SHEET 6)
-S7SP: SSMB-P-C-XX-ST-CA1 (SEE SHEET 7)
-S7RP: SSMB-P-C-XX-RA-CA1 (SEE SHEET 7)
(316 OPTION ONLY) (SEE SHEET 5)
END 1 PLATING OPTION
-13GJ: GRFS-J-C-X-ST-CA1
1: GOLD ALL COMPONENTS
2: GOLD / NICKEL COMBINATION
3: ALTERNATE GOLD / NICKEL
4: ALTERNATE GOLD / GOLD FLASH / NICKEL
7. ALTERNATE GOLD MEDIUM/ GOLD FLASH
(SEE SHEET 3 FOR PLATING SPECIFICS)
(316 OPTION ONLY) (SEE SHEET 6)
-01SB: SMA-J-C-X-ST-SB1 (SEE SHEET 6)
-01SR: SMA-J-C-X-ST-SR1 (SEE SHEET 6)
-01PN: SMA-J-C4-XX-ST-PN1 (SEE SHEET 6)
-S7SP: SSMB-P-C-XX-ST-CA1 (SEE SHEET 7)
-S7RP: SSMB-P-C-XX-RA-CA1 (SEE SHEET 7)
-SING: SINGLE ENDED (ONE END ONLY, SEE NOTE 11)
-XXXXXX: STRIPPED AND TINNED (THIS END ONLY-
SEE NOTES 11-15, 18 & SHEET 6, FIG. 3)
(SEE FIG. 2) "C" FORMAT: X.X mm
(SEE FIG. 2) "B" FORMAT: X.X mm
(SEE FIG. 2) "A" FORMAT: X.X mm
C
FIG.1
RFXXX-01SPX-01RPX-XXXX SHOWN
NOTES:
DO NOT LEAVE ANY SPACE BLANK,
EACH MUST CONTAIN A
NUMERIC CHARACTER 0 THRU 9.
1. C REPRESENTS A CRITICAL DIMENSION.
2. CABLE CUT LENGTH:
= (LENGTH: XXXX) - (SUBTRACTOR FOR END 1) - (SUBTRACTOR FOR END 2).
(SEE TABLE 1 FOR SUBTRACTORS)
3. ASSEMBLY TO BE 100% TESTED FOR OPENS & SHORTS.
4. ASSEMBLY TO BE 100% HI-POT TESTED PER TABLE 1.
5. AFTER FINAL ELECTRICAL TESTS, LABEL EACH CABLE ASSEMBLY WITH 1 LABEL -ET
6. CRITICALS ON CONNECTOR PRINTS TO BE CHECKED IN PROCESS.
C
C
THIS PRODUCT MANUFACTURED
Pb
7. FINISHED ASSEMBLIES TO BE PACKAGED PER PACKAGING STANDARD CO-HD-WI-3040-M.
-LOCK WASHERS, NUTS, AND GASKETS TO BE SHIPPED UNASSEMBLED.
8. CABLE STOCKED IN INCHES, 1 INCH = 25.4 MILLIMETERS.
WITH LEAD-FREE PROCESSING
F:\DWG\MISC\Mktg\RFXXX-XXXXX-XXXXXX-XXXX-MKT.SLDDRW
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
9. CABLE LENGTHS LONGER THAN 1000 MILLIMETERS ARE NOT SUPPORTED BY S.I. TEST DATA.
10. MINIMUM BEND RADIUS FOR RG174 = 25.4 [1.00]
MILLIMETERS [INCHES].
TOLERANCES ARE:
RG316 = 12.7 [.50]
DECIMALS
ANGLES
2
11. FOR SING ENDED OR STRIPPED AND TINNED ASSEMBLIES: MAKE A DOUBLE ENDED
ASSEMBLY AT TWICE THE CABLE LENGTH AND TEST BEFORE CUTTING ASSEMBLY IN HALF.
12. DIM "A", "B", AND "C" HAVE A MINIMUM VALUE OF 0.0mm & A MAXIMUM VALUE OF 9.9mm.
13. PRODUCTION OF STRIP AND TIN FOR CENTER DIELECTIC USE: A.
14. PRODUCTION OF STRIP AND TIN FOR SHIELD USE: D=A+B.
.X: 0.3 [.01]
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail info@SAMTEC.com code 55322
.XX: 0.13 [.005]
.XXX: 0.051 [.0020]
MATERIAL:
SHEET SCALE: 2:1
DO NOT SCALE DRAWING
DESCRIPTION:
SEE END 1 AND END 2 ASSEMBLY PRINTS
RF316 OR RF-174 CABLE ASSEMBLY
15. PRODUCTION OF STRIP AND TIN FOR JACKET USE: E=A+B+C.
16. FOR -RA TO -RA, CONNECTORS SHOULD BOTH BE ORIENTED UP. (SEE SHEET 6, FIG. 4)
17. FOR BULKHEAD APPLICATIONS, THE END USER SHOULD TIGHTEN THE THREADED NUT TO 15
IN-LB MINIMUM.
DWG. NO.
RFXXX-XXXXX-XXXXXX-XXXX
18. FOR STRIPPED AND TINNED OPTION, ONLY THE CENTER CONDUCTOR IS TINNED.
09-10-2010
SHEET 1 OF
7
BY: TIM P.