ECONOLINE - DC/DC-Converter
RF Series, 1.25 Watt, DIP8 (Single & Dual Output)
Features
● Industry Standard Pinout
● 1kVDC & 2kVDC Isolation
● No Heatsink Required
● No Extern. Components Required
● Custom Solutions Available
● UL94V-0 Package Material
Selection Guide
Part
Number
DIP 8
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
(2kV)
(ꢀ)
70
70
78
79
80
80
70
70
75
78
80
80
RF-XX3.3S (H)
RF-XX05S (H)
RF-XX09S (H)
RF-XX12S (H)
RF-XX15S (H)
RF-XX24S (H)
RF-XX3.3D (H)
RF-XX05D (H)
RF-XX09D (H)
RF-XX12D (H)
RF-XX15D (H)
RF-XX24D (H)
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3
5
378
250
140
104
84
9
12
15
24
3.3
5
52
189
125
70
9
12
15
24
52
42
26
Specifications (Core Operating Area) and Operating Temperature / Derating-Graph
Input Voltage
10ꢀ
Capacitor Type
5ꢀ
Input Filter
Output Voltage Accuracy
Line Voltage Regulation
1,2ꢀ/1ꢀ V Input
2.50
Load Voltage Regulation
(10ꢀ to 100ꢀ full load)
3.3V output types
5V output type
9V, 12V, 15V, 24V output types
20ꢀ max.
15ꢀ max.
10ꢀ max.
1.75
1.25
0.75
0
Ripple and Noise (20MHz limited)
Efficiency at Full Load
Isolation Voltage
100mVp-p max.
70ꢀ min.
Safe Operating Area
1.000VDC min.
(also available with 2.000VDC, Suffix „H“)
Isolation Resistance (Viso = 500VDC)
Isolation Capacitance
10 GΩ min.
-40
0
50
100
85 125
Operating Temperature ˚C
150
30pF min./80pF max.
1 Second
Short Circuit Protection
Switching Frequency at Full Load
Operating Temperature
Storage Temperature
100kHz typ.
–40°C to +85°C (see Graph)
-55°C to +125°C
Package Weight
Single output types
Dual output types
1.8g
1.9g
www.recom-international.com
August 2002
EC 47