• Reinforced insulation for 250VAC working voltage
• Clearance and creepage distance >8.0mm
• 5kVAC I/P to O/P 2MOPP isolation
• 2µA patient leakage current
Features
DC/DC Converter
Regulated
Converter
• Industry standard pinout
• 4:1 wide input range
REM20-W
Description
20 Watt
4:1 Input
1.6“ x 1“
Single and Dual
Output
The REM20-W series of medical grade regulated DC/DC converters features reinforced 5kVAC/1 minute
isolation with low 2µA leakage (B, BF and CF compatible) and are 60601-1 3rd Ed. certified for 250VAC
continuous working voltage isolation. The industry standard 1.6”x1” package offers tightly regulated
single and dual outputs, with low output ripple and zero-load operation.The outputs are also short circuit
and overload protected. The converters are certified to CB, IEC/EN and ANSI/AAMI standards and carry
the UL mark.
Selection Guide
Part
Number
Input
Voltage Range
[VDC]
Output
Voltage
[VDC]
Output
Current
[mA]
Efficiency
typ. (1)
[%]
Max. Capacitive
Load (2)
[µF]
REM20-2405SW (3)
REM20-2412SW (3)
REM20-2415SW (3)
REM20-2424SW (3)
REM20-4805SW (3)
REM20-4812SW (3)
REM20-4815SW (3)
REM20-4824SW (3)
REM20-2405DW (3)
REM20-2412DW (3)
REM20-2415DW (3)
REM20-4805DW (3)
REM20-4812DW (3)
REM20-4815DW (3)
9-36
9-36
5
4000
1667
1333
833
87
88.5
88
5000
850
700
220
2500
500
350
5000
850
700
220
2500
500
350
12
15
24
5
9-36
9-36
88
18-75
18-75
18-75
18-75
9-36
4000
1667
1333
833
89.5
88
12
15
24
5
88
88.5
86
2000
833
E314885
2MOPP
9-36
12
15
5
88
9-36
667
88
250VAC
18-75
18-75
18-75
2000
833
86
UL60950-1 certified
CSA/CAN C22.2 60950-1-07 certified
UL62368-1 certified
12
15
88.5
88
667
CSA/CAN C22.2 62368-1 certified
CSA/CAN C22.2 60601-01 certified
ANSI/AAMI ES60601-1 certified
EN55011 certified
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resisitive load
CB report
Model Numbering
REM20- __ __ _ W/P
Output Power
nom. Input Voltage
nom. Output Voltage
CTRL pin option (positive logic)
Wide Input Voltage Range (4:1)
Single or Dual
Notes:
Note3: standard is with suffix „/P“ (CTRL pin with positive logic)
without suffix is without CTRL pin (no pin) please refer to dimensions drawing
Ordering Examples:
REM20-2412SW/P = 4:1 Input, 9-36Vin, 12Vout, with control pin positive logic
REM20-4815DW = 4:1 Input, 18-75Vin, 15Vout, without control pin
www.recom-power.com
REV.: 0/2018
MED-1