● UL-60950-1 / CSA C22.2 certified
● 5W DIP Package
● 4kVDC & 6kVDC Isolation
● Regulated Output
● Continuous Short Circuit Protection
● Wide Input 2:1 & 4:1
● UL94V-0 Package Material
● 100% Burned In
ECONOLINE
Features
DC/DC-Converter
Regulated
Converters
REC5-
S_DRW/H4,
H6 Series
● Efficiency to 86%
Selection Guide
5 Watt
Part
Input
Voltage
(VDC)
Output Max. Cap. Output
Efficiency
(%)
Number
DIP24 (SMD)
Voltage
(VDC)
Load
(µF)
Current
(mA)
DIP24 & SMD
Single & Dual
Output
REC5-xx3.3SRW (H4/H6)
REC5-xx05SRW (H4/H6)
(See Notes)
9 - 18, 18 - 36, 36 - 72
9 - 18, 18 - 36, 36 - 72
4.5 - 9
3.3
5
2200
1000
1200
1000
75-77
79-81
72
REC5-xx09SRW (H4/H6)
(See Notes)
9 - 18, 18 - 36, 36 - 72
4.5 - 9
9
470
220
120
470
100
68
556
420
340
500
210
170
82-83
73
REC5-xx12SRW (H4/H6)
(See Notes)
9 - 18, 18 - 36, 36 - 72
4.5 - 9
12
15
5
84-85
74
REC5-xx15SRW (H4/H6)
(See Notes)
9 - 18, 18 - 36, 36 - 72
4.5 - 9
85-86
75
REC5-xx05DRW (H4/H6)
(See Notes)
9 - 18, 18 - 36, 36 - 72
4.5 - 9
79-81
72
REC5-xx12DRW (H4/H6)
(See Notes)
9 - 18, 18 - 36, 36 - 72
4.5 - 9
12
15
84-85
74
REC5-xx15DRW (H4/H6)
(See Notes)
9 - 18, 18 - 36, 36 - 72
4.5 - 9
85-86
75
EN-60950-1 Certified
UL-60950-1 Certified
EN-60601-1 Certified
REC5-xx3.3SRWZ (H4/H6)
REC5-xx05SRWZ (H4/H6)
REC5-xx09SRWZ (H4/H6)
REC5-xx12SRWZ (H4/H6)
REC5-xx15SRWZ (H4/H6)
REC5-xx05DRWZ (H4/H6)
REC5-xx12DRWZ (H4/H6)
REC5-xx15DRWZ (H4/H6)
9 - 36**, 18 - 72
9 - 36**, 18 - 72
9 - 36, 18 - 72
9 - 36, 18 - 72
9 - 36, 18 - 72
9 - 36, 18 - 72
9 - 36, 18 - 72
9 - 36, 18 - 72
3.3
5
2200
1000
470
220
120
470
100
68
1200
1000
556
420
340
500
210
170
75-76
81-82
82-83
83-84
84-85
81-82
82-83
84-85
9
12
15
5
12
15
2:1 Input (REC5-S/DRWH4/H6)
xx = 4.5-9Vin = 05
4:1 Input (REC5-S/DRWZ(H4/H6))
xx = 9-36Vin = 24
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-72Vin = 48
xx = 18-72Vin = 48
Description
This series offers high isolation of 4kVDC
(= option "/H4") or 6kVDC (= option "/H6")
making it ideal for medical applications and
other sophisticated industrial applications.
Notes :
Packaging can be either DIP-24 non-conduct-
ive plastic or 5-side-shielded DIP24 metal
case (= option "M") as well as DIP24-SMD
case (= option "SMD").
For the REC5-05xxS_DRW/H4/H6 series, Load = 90%max. when Vin=4.5VDC.
* add suffix "/H4" for 4kVDC isolation or "/H6" for 6kVDC isolation
* add suffix "/A" or "/C" for Pinning, see next page
For all the above variants, 2 industry-standard
pinouts (= option "A" or "C") are available.
* add suffix "/M" for metal case
* add suffix "/SMD" for SMD package
e.g. REC5-xxxxSRWZ/H4/AM = 4kVDC isol. / Pinout "A" / metal case
** 24V 4:1 Wide Range Input Types (REC5-24xxS_DRWZ(/H4/H6)) should be derated Vin= 9 Vin : 3.3Vout /
1100mA max., 5Vout / 900mA max..
If the options "/M" for metal case and "/SMD" for SMD pinout are combined the maximum allowed isolation
voltage is 2kVDC because of the shorter distances between the pins and the metal-case so the only availa-
ble SMD-option in metal-case is "/H2". DIP-24 through-hole case and SMD-plastic case are not affected
and offer the full isolation barriers of 4kVDC for "/H4" option and 6kVDC for "/H6".
November 2006