ECONOLINE - DC/DC-Converter
REC5-S/DRW Ser., 5W, DIP24, Regul., Wide Input 2:1 & 4:1 (Single & Dual Output)
Selection Guide
Part
Number
DIP24
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
(ꢀ)
75
80
80
81
75
80
81
74
76
78
80
81
81
81
REC5-XX05SRW*
REC5-XX09SRW*
REC5-XX12SRW*
REC5-XX15SRW*
REC5-XX05DRW*
REC5-XX12DRW*
REC5-XX15DRW*
REC5-XX05SRWZ*
REC5-XX09SRWZ*
REC5-XX12SRWZ*
REC5-XX15SRWZ*
REC5-XX05DRWZ*
REC5-XX12DRWZ*
REC5-XX15DRWZ*
9-18, 18-ꢂ6, ꢂ6-72
9-18, 18-ꢂ6, ꢂ6-72
9-18, 18-ꢂ6, ꢂ6-72
9-18, 18-ꢂ6, ꢂ6-72
9-18, 18-ꢂ6, ꢂ6-72
9-18, 18-ꢂ6, ꢂ6-72
9-18, 18-ꢂ6, ꢂ6-72
9-ꢂ6, 18-72
5
9
1000
556
470
400
500
2ꢂ0
190
1000
556
470
400
500
2ꢂ0
190
12
15
5
Features
● 5W DIP Package
● 9-18V, 18-ꢂ6V, ꢂ6-72V
Wide Input Range
● Short Circuit Protection
● Regulated Output
● UL94V-0 Package Material
● Efficiency to 81ꢀ
12
15
5
9-ꢂ6, 18-72
9
9-ꢂ6, 18-72
12
15
5
9-ꢂ6, 18-72
9-ꢂ6, 18-72
9-ꢂ6, 18-72
12
15
9-ꢂ6, 18-72
XX = 9-18Vin = 12
XX = 18-ꢂ6Vin = 24
XX = ꢂ6-72Vin = 48
XX = 9-ꢂ6Vin = 24
XX = 18-72Vin = 48
*add „%A“ or „% B“ for Pinning,
see neꢁt page.
Specifications (Core Operating Area) and Operating Temperature / Derating-Graph
Voltage Setting Accuracy
Temperature Coefficient
Ripple and Noise (20MHz BW)
Line Regulation (HL-LL)
Load Regulation (for output load current change from 10ꢀ to 100ꢀ)
Short Circuit Protection
Operating Temperature
Storage Temperature
Cooling
2ꢀ maꢁ.
0.0ꢂꢀ%/C
100mVp-p maꢁ.
0.2ꢀ maꢁ.
0.2ꢀ maꢁ.
10.0
7.5
5.0
2.5
0
Continuous
-25/C to +70/C (see Graph)
-55/C to +100/C
Free-Air Convection
Pi Network
Safe Operating Area
-25
0
25 50 75 100 125
70 90
Operating Temperature ˚C
Input Filter
Efficiency
70ꢀ min.
Isolation Voltage
1.000VDC min.
109 ohms min.
25kHz min.
Isolation Resistance
Switching Frequency at Full Load
Isolation Capacitance
Weight
80pF maꢁ.
14.6g
Case Material
Non-Conductive Plastic
www.recom-international.com
August 2002
EC 79