5秒后页面跳转
RA6050-D16 PDF预览

RA6050-D16

更新时间: 2024-11-24 23:32:03
品牌 Logo 应用领域
其他 - ETC /
页数 文件大小 规格书
4页 119K
描述

RA6050-D16 数据手册

 浏览型号RA6050-D16的Datasheet PDF文件第2页浏览型号RA6050-D16的Datasheet PDF文件第3页浏览型号RA6050-D16的Datasheet PDF文件第4页 
Solid State Relays  
Industrial, 1-Phase ZS (IO), High Volt./Current Range  
Types RA 60 50 -D 16, RA .. 90 -D .., RA .. 110 -D..  
High-current, high-voltage  
AC Solid State Relay  
Zero switching or instant-on switching  
Rated operational current: 50, 90 and 110 AACrms  
Non-repetitive voltage: Up to 1600 Vp  
Rated operational voltage: Up to 600 VACrms  
High surge current capability  
Insulation: OPTO (input-output) 4000 VACrms  
Product Description  
Ordering Key  
RA 60 110 -D 16  
These high-current, high-volt- ves and solenoids as well as Solid State Relay  
age solid state relays are all resistive loads. Both a zero Switching mode  
designed for ON-OFF or phase crossing and an instant-on Rated operational voltage  
controlling of high-power AC drive circuit will minimize the Rated operational current  
applications. High current and negative effects of different Control voltage  
high dV/dt capabilities will al- load types. Optocouplers pro- Non-rep. peak voltage  
low switching of inductive loads vide an ideal interface to logic  
e.g. transformers, motors, val- level DC-outputs.  
Type Selection  
Switching mode  
Rated operational  
voltage  
Rated operational  
current  
Control voltage  
Non-rep. voltage  
A: Zero switching  
Optional:  
B. Instant-on switching 48: 480 VACrms  
60: 600 VACrms  
24: 230 VACrms  
40: 400 VACrms  
50: 50 AACrms  
90: 90 AACrms  
110: 110 AACrms  
-D: 4.5 to 32 VDC  
06: 650 Vp  
10: 1000 Vp  
12: 1200 Vp  
16: 1600 Vp  
Selection Guide  
Rated operational Non-rep. voltage  
voltage  
Control voltage  
Rated operational current  
50 AACrms  
90 AACrms  
110 AACrms  
230 VACrms  
400 VACrms  
480 VACrms  
600 VACrms  
650 Vp  
1000 Vp  
1200 Vp  
1600 Vp  
4.5 to 32 VDC  
4.5 to 32 VDC  
4.5 to 32 VDC  
4.5 to 32 VDC  
*
RA 2490 -D 06  
RA 24110-D 06  
RA 40110-D 10  
RA 48110-D 12  
RA 60110-D 16  
*
RA 4090 -D 10  
RA 4890 -D 12  
RA 6090 -D 16  
*
RA 6050 -D 16  
* Please refer to standard range, RA-relays.  
General Specifications  
RA 24 .. -D 06  
RA 40 .. -D 10  
RA 48 .. -D 12  
RA 60 .. -D 16  
Operational voltage range  
Non-rep. peak voltage  
Zero voltage turn-on  
Operational frequency range  
Power factor  
24 to 280 VACrms  
650 Vp  
15 V  
45 to 65 Hz  
0.5 @ 400 VACrms  
CSA, UL  
24 to 440 VACrms  
1000 Vp  
15 V  
45 to 65 Hz  
0.5 @ 400 VACrms 0.5 @ 480 VACrms  
24 to 530 VACrms  
1200 Vp  
15 V  
24 to 690 VACrms  
1600 Vp  
20 V  
45 to 65 Hz  
0.5 @ 690 VACrms  
45 to 65 Hz  
Approvals  
CSA, UL  
CSA, UL  
CSA (max 600 VAC),  
UL  
CE-marking  
Yes  
Yes  
Yes  
Yes  
Specifications are subject to change without notice (30.06.1999)  
1

与RA6050-D16相关器件

型号 品牌 获取价格 描述 数据表
RA6050-D16D ETC

获取价格

RA6090-D16 ETC

获取价格

RA6090-D16D ETC

获取价格

RA60H1317M MITSUBISHI

获取价格

RoHS Compliance ,135-175MHz 60W 12.5V, 3 Stage Amp. For MOBILE RADIO
RA60H1317M_06 MITSUBISHI

获取价格

RoHS Compliance ,135-175MHz 60W 12.5V, 3 Stage Amp. For MOBILE RADIO
RA60H1317M_10 MITSUBISHI

获取价格

135-175MHz 60W 12.5V, 3 Stage Amp. For MOBILE RADIO
RA60H1317M_11 MITSUBISHI

获取价格

RoHS Compliance , 135-175MHz 60W 12.5V, 3 Stage Amp. For MOBILE RADIO
RA60H1317M-01 MITSUBISHI

获取价格

135-175MHz 60W 12.5V MOBILE RADIO
RA60H1317M-101 MITSUBISHI

获取价格

RoHS Compliance ,135-175MHz 60W 12.5V, 3 Stage Amp. For MOBILE RADIO
RA60H1317M1A MITSUBISHI

获取价格

RoHS Compliance ,136-174MHz 60W 12.5V, 2 Stage Amp. For MOBILE RADIO