HARTMAN Sensors and Protective Devices
RA-3100 Series Remote Power Controller, Rated up to 60 Amps, 115/208 VAC
Product Facts
n 3PST NO
n Gasket sealed
Performance Data
Electrical Characteristics
Contact Arrangement — 3PST NO
Rated Operating Voltage —
115/208 VAC, 400-610 Hz, 3 phase
Resistive Rating — 50 Amp
Motor Rating — 30 Amp
Rupture Rating — 1000 Amp
Closing Time, Max., Override at
28 Vdc — 35 msec
Opening Time, Max., Override at
28 Vdc — 25 msec
Contact Bounce, Max. — 3 msec
Coil Characteristics
Duty Cycle — Continuous,
economizing
Operating Voltage, Max. — 32 Vdc
Operating Voltage @ 85°C, Min. —
18 Vdc
Trip Time @ 60 Amp Current
+10% — 2.0 to 3.0 sec
Trip Time @ 75 Amp Current +10%
— 1.0 to 1.9 sec
Trip Time @ 95 Amp Current +10%
— .2 to .9 sec
Trip Time @ 200+ Amp Current
+10% — 0.01 to 0.1 sec
Mounting Style A
Circuit Configurations (Consult factory for other available circuit
configurations)
General Characteristics
Temperature Range —
-55°C to +85°C
Operating Cycles (Life)
Mechanical, Min. — 100,000 cycles
Altitude — 50,000 ft
Weight, Max. — 1.55 lbs
Circuit Configuration 1
HARTMAN
Part Number
Construction
Type
Mounting
Style
Coil
Type
Circuit
Config.
TE
Part Number
For factory-direct application
assistance, phone 419-521-9500 or
fax 419-526-2749.
Continuous,
Economizing
RA-3100H
Gasket/Vented
A
1
1616539-3
6–146
Catalog 5-1773450-5
Revised 3-13
Dimensions are shown for
Dimensions are in millimeters
unless otherwise specified.
USA: +1 800 522 6752
Asia Pacific: +86 0 400 820 6015
UK: +44 800 267 666
For additional support numbers
please visit www.te.com
reference purposes only.
Specifications subject
to change.
www.te.com