MODEL: R3-NC3
Remote I/O R3 Series
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
CC-Link INTERFACE MODULE
(CC-Link Ver. 2)
/C02: Polyurethane coating
/C03: Rubber coating
27.5 [1.08]
EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet
(No. ESU-8422)
130
[5.12]
PACKAGE INCLUDES...
• Terminating resistor (110 Ω, 0.5 W)
109
[4.29]
GENERAL SPECIFICATIONS
Connection
mm [inch]
CC-Link: Euro type connector terminal
(applicable wire size: 0.2 to 2.5 mm , stripped length 7 mm)
2
MODEL: R3-NC3-[1][2]
Internal bus: Via the Installation Base
(model: R3-BSx)
ORDERING INFORMATION
• Code number: R3-NC3-[1][2]
Internal power: Via the Installation Base (model: R3-BSx)
Power input, RUN contact output: M3 separable screw
terminal (torque 0.5 N·m)
Specify a code from below for each of [1] and [2].
(e.g. R3-NC3-N/CE/W/Q)
Screw terminal: Nickel-plated steel
• Specify the specification for option code /Q
(e.g. /C01/SET)
Isolation: CC-Link to internal bus or internal power to power
supply to RUN contact output to FG
Dual communication setting: Set with the side DIP switch
Data allocation setting: Set with the side DIP switch
RUN indicator: Bi-color (green/red) LED; Green ON in normal
communication; Red ON when receiving data (Function
selected with DIP SW)
[1] POWER INPUT
N: No power supply
AC Power
K3: 100 – 120 V AC
ERR indicator: Bi-color (green/red) LED;
(Operational voltage range 85 - 132 V, 47 - 66 Hz) *
(CE not available)
Green ON or blinking at communication error (OFF with
cable disconnection, blinking in setting error); Red ON at
transmitting data (Function selected with DIP SW)
■ RUN CONTACT OUTPUT
L3: 200 – 240 V AC
(Operational voltage range 170 - 264 V, 47 - 66 Hz) *
(CE not available)
RUN contact: Turns ON while the green RUN LED is ON (CC-
Link in normal communication).
DC Power
R: 24 V DC
Rated load: 250 V AC @ 0.5 A (cos ø = 1)
30 V DC @ 0.5 A (resistive load)
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) *
* Not selectable for use with independent power modules or
network modules with the internal power input options.
(Less than 50 V AC to conform with EU Directive)
Maximum switching voltage: 250 V AC or 30 V DC
Maximum switching power: 250 VA or 150 W
Minimum load: 1 V DC @ 1 mA
[2] OPTIONS (multiple selections)
Standards & Approvals
blank: Without CE
Mechanical life: 2 × 10 cycles (300 cycles/min.)
7
When driving an inductive load, external contact protection
and noise quenching recommended.
/CE: CE marking
Mitsubishi PLC Redundant System
blank: Without
CC-Link COMMUNICATION
CC-Link: Conforms to Version 2.00
(incompatible with Ver. 1)
/W: With
Other Options
blank: none
Cyclic expansion setting: 2, 4, 8 folds (Function selected
with DIP switch)
/Q: Option other than the above (specify the specification)
R3-NC3 SPECIFICATIONS
ES-8422 Rev.20 Page 1/8