• Qualified with 65kV/µs @ Vcommon mode =1KV
• EN61010 for test, measurement and lab use
• EN60601 for medical applications
• Reinforced isolation 6.4kVDC or 8kVDC
• Optional continuous short circuit protection
• Unique reinforced isolation transformer system
• /X2 option for >9mm input/output clearance
Features
DC/DC Converter
Unregulated
Converters
RxxPxx/R
Description
1 Watt
SIP7
The RxxPxxS_D Series of DC/DC Converters are certified to UL/CSA60950-1. This makes them ideal for
safety applications where approved or reinforced isolation is required. The reinforced versions are also
EN61010-1 certified for Lab Equipment Safety.
3
Single and Dual
Output
Selection Guide
Part
Number
nom. Input
Voltage
[VDC]
Output
Voltage
[VDC]
Output
Current
[mA]
Efficiency
typ. (1)
[%]
max. Capacitive
Load (2)
[µF]
RxxP3.3S/R(3,4,5)
RxxP05S/R(3,4,5)
RxxP09S/R(3,4,5)
RxxP12S/R(3,4,5)
RxxP15S/R(3,4,5)
RxxP3.3D/R(3,4,5)
RxxP05D/R(3,4,5)
RxxP09D/R(3,4,5)
RxxP12D/R(3,4,5)
RxxP15D/R(3,4,5)
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
3.3
5
303
200
111
84
70 - 80
75 - 80
75 - 82
75 - 82
75 - 83
72 - 79
75 - 82
75 - 82
75 - 82
75 - 83
2200
1000
1000
470
9
12
15
3.3
5
66
470
151
100
55
1000
470
9
470
12
15
41
220
33
220
RoHS2
+
REACH
compliant
compliant
10 from 10
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max. Capacitive Load is defined as the capacitive load that will allow start up
in under 1 second without damage to the converter
E314885
Model Numbering
UL/CSA60950-1 certified
IEC/EN60950-1 certified
UL/ES/CSA60601-1 certified
IEC/EN60601-1 certified
IEC/EN61010-1 certified
CB report
R__P__ _/P/X2/R
(3)
“Reinforced Isolation
”
Input Voltage
Output Voltage
Single or Dual
(4)
“Pinout
”
(5)
“Protection
”
Notes:
Note3: add suffix „/R6.4“ for 6.4kVDC/1second isolation or „/R8“ for 8kVDC/1second isolation
Note4: add suffix „/X2“ for single output with alternative pinout
Note5: add suffix „/P“ for continous short circuit protection
Ordering Examples:
REF
dv/dt
R05P3.3S/R8/P = 5V Input, 3.3V Output, Single Output, 8kVDC/1s isolation, Continous Short Circuit Protection
R24P05S/R6.4/P/X2 = 24V Input, 5V Output, Single Output, 6.4kVDC/1s isolation, Continous SCP, Alternative Pinout
R12P05D/R8/X2 = 12V Input, 5V Output, Dual Output, 8kVDC/1s isolation, Alternative Pinout
DESIGN