1
R15
Plug-in power relays
• R15 2C/O, R15 3C/O - WT standard plug-in version
with indicating flag and manual testing/latching lever
• Cadmium - free contacts available
• Wide range of accessories
• Current coil version available on request
• Maritime and rail-way version available
• Plug-in, solder, PCB, connector mounting
Contacts
Contact number & arrangement
Contact material
2C/O, 3C/O, 4C/O
2C/O, 3C/O: AgCdO;AgNi; AgNi/Au 0,2 µm; AgNi/Au 5 µm
4C/O: AgCdO; AgCdO/Au 0,2 µm; AgCdO/Au 5 µm
Voltage
Max. switching voltage AC/DC
Min. switching voltage
250 V / 250 V
5 V (AgNi/Au 5 µm, AgCdO/Au 5 µm)
5 V (AgNi, AgNi/Au 0,2 µm)
10 V (AgCdO, AgCdO/Au 0,2 µm)
Current
Rated load
AC1
DC1
10 A / 250 V AC
10 A / 24 V DC
2 mA (AgNi/Au 5 µm, AgCdO/Au 5 µm)
5 mA (AgNi, AgNi/Au 0,2 µm)
10 mA (AgCdO, AgCdO/Au 0,2 µm)
20 A
Min. switching current
Max. inrush current
Rated current
Max. breaking capacity
10 A
2 500 VA
AC1
AC1
0,05 W (AgNi/Au 5 µm, AgCdO/Au 5 µm)
0,3 W (AgNi, AgNi/Au 0,2 µm)
0,5 W (AgCdO, AgCdO/Au 0,2 µm)
£
Min. breaking capacity
Resistance
100 mW
at 100 mA, 24 V
Max. operating frequency
at rated load
no load
cycles/hour
1 200
cycles/hour
12 000
•
•
Coil
Voltage
Rated voltage
6...220 V DC
6...240 V AC 50 Hz, 50/60 Hz
Must release voltage
Operating range of supply voltage
Rated power consumption
n
³ 0,1 U DC; ³ 0,15 Un AC
see Tables 1, 2, 3, 4
2,8 VA 50 Hz AC; 2,5 VA 60 Hz; 1,5 W DC
Insulation
Insulation category
Voltage
C250
Insulation rated voltage
Dielectric strength
• coil-contact
• contact-contact
• pole-pole
250 V AC
2 500 V AC
1 500 V AC
2 000 V AC
Contact-coil distance
• clearance
• creepage for
2C/O, 3C/O, 4C/O: ³ 3 mm
2C/O, 3C/O: ³ 4,2 mm; 4C/O: ³ 3,2 mm
General data
Operating time (typical value)
Release time (typical value)
Electrical life
12 ms DC; 12 ms AC
7 ms DC; 10 ms AC
• resistive
³
2 x 105
see Fig. 2
³
2 x 107
at 10 A, 250 V AC
• cos j
Mechanical life (cycles)
Dimensions (L x W x H)
2C/O, 3C/O: 35 x 35 x 54,4 mm
4C/O: 35 x 42,5 x 54,5 mm
2C/O, 3C/O: 83 g; 4C/O: 95 g
Weight
Ambient temperature
• storing
• operating
-40...+85 °C
DC: -40...+70 °C; AC: -40...+55 °C
Cover protection category
Shock resistance
Vibration resistance
IP 40
10 g
5 g
for 10...150 Hz
Solder bath temperature
Soldering time
Approvals
max. 270 °C
max. 5 s
B, UL, CSA, SEV, EZU, VDE, GOST