QSE-XXX-01-XXX-D-XXX
C
REVISION AZ
No OF POSITIONS
OPTION
((No OF POSITIONS / 20) x .7875[20.003]) + .0500[1.270] REF
-020, -040, -060
-A: ALIGNMENT PINS
.0975 2.477
REF
*-080, *-100 (PER ROW)
(USE QSE-20-XX-D-XX-A)
NA WITH -LC OPTION
.7875 20.003
DO NOT
SCALE FROM
THIS PRINT
LEAD STYLE
-01 .1280[3.251]
-LC: LOCKING CLIPS(SEE NOTE 14)
(USE LC-08-TM-01, )
NA WITH -A OPTION
-GP: GUIDE POSTS (SEE FIG 3, SHT 2)
(USE QSE-20-01-D-XX-X-GP)
(T & R PACKAGING: 40 POS MAX)
-K: POLYIMIDE FILM
.1195 3.035
REF
PLATING SPECIFICATION
19 EQ. SPACES
@ .0315 [.800]
PLATING THICKNESSES ARE FOR
SIGNAL PINS ONLY. FOR GROUND
PLANE THICKNESSES, SEE PP-T-1G2-XX-X.
(SEE NOTES 8, 11 & 13)
-F: 3µ" SELECTIVE GOLD CONTACT,
MATTE TIN TAIL
(USE C-126-21-F, T-1G2-01-F)
-L: 10µ" SELECTIVE GOLD CONTACT,
MATTE TIN TAIL
02
01
(USE K-DOT-.325-.450-.005, SEE FIG 2, SHT 2)
-TR: TAPE & REEL (60 POS MAX)
(SEE FIG 7, SHT 3)
.285 7.24
REF
AZ
(40 POS MAX -GP OPTION)
-FL: FRICTION LOCKS
.6250 15.875
(SEE FIG 4, SHT 2)
.0060 0.152 REF
(USE C-126-21-L, T-1G2-01-L)
-H: 30µ" GOLD CONTACT, 3µ" GOLD TAIL
(USE C-126-21-H, T-1G2-01-G)
-C: 50µ" ELECTRO POLISHED SELECTIVE
GOLD CONTACT, MATTE TIN TAIL
(USE C-126-21-C, T-1G2-01-L)
-STL: 30µ" SELECTIVE GOLD CONTACT,
TIN LEAD (90/10 ±5%) TAILS
REF
(NOT AVAILABLE WITH -GP)
-RT1: RETENTION OPTION
(MUST USE -A OPTION)
.0225 0.571
REF
QSE-20-01-D-XX-X
SEE NOTE 15
(USE QSE-20-01-D-XX-A-RT1 &
SUB-SC-05-01-FF)
"A"
"A"
.055 1.40
.120 3.05
REF
(SEE FIG 5, SHT 2)
(NOT AVAILABLE WITH -LC, -GP, OR -FL)
(NOT AVAILABLE WITH -100 POS)
-L: LATCHING OPTION (40 POS MAX)
(SEE FIG 6, SHT3)
(USE C-126-21-STL, T-1G2-01-STL)
-FTL: 3µ" SELECTIVE GOLD CONTACT,
TIN LEAD (90/10 ±5%) TAILS
LC-08-TM-01
.010 0.25 REF
(MUST USE -A OPTION)
(NOT AVAILABLE WITH -LC, -GP, -FL,
OR -RT1)
(USE C-126-21-FTL, T-1G2-01-FTL)
-LTL: 10µ" SELECTIVE GOLD CONTACT,
TIN LEAD (90/10 ±5%) TAILS
.7250 18.415 REF
(USE C-126-21-LTL, T-1G2-01-LTL)
-S: 30µ" SELECTIVE GOLD CONTACT,
MATTE TIN TAIL
ROW SPECIFICATION
-D: DOUBLE
.007 0.18
REF
T-1G2-01-XXX
(USE QSE-20-XX-D-XX)
(USE C-126-21-S, T-1G2-01-L)
No OF BANKS
* SEE NOTE 12
C
(((No OF POSITIONS / 20) x .7875[20.003]) + .005[.13]) .003
.0375 0.953
+.0030
-.0010
+0.076
3.251
-0.025
.1280
C-126-21-XXX
(SEE NOTE 13)
(SEE NOTE 6 & 7)
.0375 0.953
REF
SEE TABLE 1
C
R
.0375 0.953
REF
.0350 0.889 REF
.056 1.42 REF
.2950 7.493 REF
(((No OF POSITIONS / 20) x .7875[20.003]) +.005[.13]) REF
-A: ALIGNMENT PIN OPTION SHOWN
SECTION "A"-"A"
NOTES:
C
1.
REPRESENTS A CRITICAL DIMENSION.
2. MIN CONTACT RETENTION: 8 OZ
3. MIN GROUND PLANE RETENTION: 8 OZ
FIG 1
4. PARTS ARE MOLDED TO POSITION.
QSE-060-01-XXX-D-LC SHOWN
5. DELETED.
6. MAX VARIANCE: .002[0.51].
7. DIMENSION APPLIES TO CONTACTS & GROUND PLANE.
8. -L PLATING CAN BE SUBSTITUTED FOR -F PLATING, -G PLATED GROUND
PLANE CAN BE SUBSTITUTED FOR -F PLATED GROUND PLANE.
9. GROUND PLANE PRESS HEIGHT MUST BE .003 [0.08] LESS THAN THE MAX HEIGHT OR .001 [0.03]
GREATER THAN THE MINIMUM HEIGHT OF THE SOCKETS.
10. S-103 RETENTION: 1 LB MIN IN BODY.
PROPRIETARY NOTE
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DECIMALS
ANGLES
2
.XX: .01[.3]
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail info@SAMTEC.com code 55322
.XXX: .005[.13]
11. MAY SUB C-126-01-XXX FOR C-126-21-XXX.
.XXXX: .0020[.051]
12. FOR NEW APPLICATIONS REQUIRING THESE POSITIONS, PLEASE CONTACT
SAMTEC INTERCONNECT PROCESSING GROUP.
MATERIAL:
DO NOT SCALE DRAWING
SHEET SCALE: 2:1
DESCRIPTION:
.8mm DOUBLE ROW HS SOCKET ASSEMBLY
INSULATOR: LCP, COLOR: BLACK, UL 94 VO
CONTACT: PHOS BRONZE
13. FOR -080, -100 POSITIONS USE C-269-11-XXX. DO NOT SUB C-126.
14. DUE TO THE HIGH AMOUNT OF INSERTION FORCE NEEDED, THE -LC OPTION IS NOT COMPATIBLE WITH
AUTO PLACEMENT.SAMTEC RECOMMENDS MANUAL PLACEMENT FOR ALL ASSEMBLIES WITH
THE -LC OPTION.
DWG. NO.
GROUND PLANE: PHOS BRONZE
QSE-XXX-01-XXX-D-XXX
15. SIDE WALLS ARE RIBBED AS NECESSARY TO CONTROL BOW.
BY:
ERIC M
05/20/1999 SHEET 1 OF 3
F:\DWG\MISC\MKTG\QSE-XXX-01-XXX-D-XXX-MKT.SLDDRW