1
6 ⁄ -Digit Digital Multimeter, 1.8 MS/s
2
Isolated Digitizer, and LCR Meter
NI PXI-4072
• Multifunction device
Operating Systems
• Windows Vista/XP/2000
• Linux®
1
• 6 ⁄
2-digit digital multimeter
• 1.8 MS/s isolated digitizer
• LCR meter (inductance,
capacitance, and resistance)
• 20 built-in measurements
• 10- to 23-bit flexible resolution
• Built-in self-calibration
Recommended Software
• LabVIEW
• LabVIEW Real-Time Module
• LabWindows™/CVI
• LabVIEW SignalExpress
•
300 VDC/Vrms isolation
• 425 Vp AC measurements
Driver Software (included)
• NI-DMM driver
• DMM Express VI for LabVIEW
• DMM Soft Front Panel
Calibration
• Gain, temperature, and offset
self-calibration
• 2-year external calibration cycle
Mode
Capacitance
Ranges
300 pF, 1 nF, 10 nF, 100 nF, 1 µF, 10 µF
100 µF, 1000 µF, 10,000 µF
10 µH, 100 µH
Reading Rate (S/s)
Overview
20
3
40
20
3
The National Instruments PXI-4072 FlexDMM, based on the NI 4070
architecture, combines the functionality found in three common test
instruments – a digital multimeter, an LCR meter, and a digitizer. This
functionality provides engineers with the 20 most common test functions
in a compact 3U PXI module, including voltage, current, capacitance,
inductance, temperature, and resistance. Integrating these measurements
in a PXI module reduces test system size and cost, increases throughput,
and shortens test development time, making the NI PXI 4072 an
excellent fit for use in automated tests on both the production floor and
Inductance
1 mH, 10 mH
100 mH, 1 H, 5 H
Table 1. PXI-4072 Key Specifications
in an R&D environment.
1
The PXI-4072 offers a DC reading rate from 10 kS/s at 4 ⁄
2
digits
to 5 S/s at 7 digits. As a digitizer, the FlexDMM can acquire both AC-
and DC-coupled voltage and current waveforms up to 300 V and 1 A
input at a maximum sampling rate of 1.8 MS/s. As an LCR meter, the
FlexDMM delivers 0.25 percent basic accuracy for both inductance and
capacitance at measurement rates up to 40 S/s. Using the intuitive
NI-DMM instrument driver, you can quickly change from function to
function in a single application programming interface (API).
Ordering Information
NI PXI-4072............................................................................778270-01
Includes the P-1 Probe Set, NI-DMM, DMM Express VI, and DMM Soft Front Panel.
Recommended Switching and Accessories
NI PXI-2527
300 V multiplexer switch ................................................ 778572-27
NI PXI-2530
128x1 multiplexer switch..................................................778660-01
P-1 Probe Set (standard probe) ............................................761000-01
P-2 Probe Set (additional probe) ..........................................184698-01
P-3 Probe Set (banana plug to bare wire) ............................185692-01
10 A current shunt, CSM-10A ..............................................777488-02
BUY NOW!
For complete product specifications, pricing, and accessory information,
call 800 813 3693 (U.S.) or go to ni.com/dmm.