15~40W AC-DC Single Output Desktop
P40A series
Features :
3 pole AC inlet IEC320-C14
Class power ( with earth pin)
Full output 3~48V safety approval
Protections: Short circuit / Overload / Over voltage / Over temp.
Fully enclosed plastic case
Fix switching frequency and regulation
Topology: Top switch circuit
LED indicator for power on
Approvals: UL / CUL / TUV / CB / CE
2 years warranty
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
SPECIFICATION
ORDER NO.
P40A-0P2J P40A-1P2J P40A-1-1P2J P40A-2P2J P40A-3P2J P40A-4P2J P40A-5P2J P40A-6P2J P40A-7P2J P40A-8P2J
SAFETY MODEL NO.
PSU40A-0 PSU40A-1 PSU40A-1-1 PSU40A-2 PSU40A-3 PSU40A-4 PSU40A-5 PSU40A-6 PSU40A-7 PSU40A-8
DC VOLTAGE
Note.2 3.3V
5V
5A
7.5V
9V
12V
15V
18V
24V
28V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
4.54A
4A
3.88A
0 ~3.88A
35W
3.33A
2.66A
2.22A
1.66A
1.42A
0.83A
0 ~ 4.54A 0 ~ 5A
0 ~ 4A
30W
0 ~ 3.33A 0 ~ 2.66A 0 ~ 2.22A 0 ~ 1.66A 0 ~ 1.42A 0 ~ 0.83A
15W
25W
40W
40W
40W
40W
40W
40W
RIPPLE & NOISE (max.) Note.3 50mVp-p
50mVp-p
5~6V
80mVp-p
6~8V
80mVp-p
8~11V
80mVp-p
11~13V
100mVp-p 100mVp-p 150mVp-p 150mVp-p 150mVp-p
OUTPUT
3~5V
13~16V
16~21V
21~27V
27~33V
33~48V
VOLTAGE ADJ. RANGE
Fixed output by internal VR
VOLTAGE TOLERANCE Note.4 10%
6.0%
1.0%
5.0%
5.0%
1.0%
5.0%
5.0%
1.0%
4.0%
4.0%
1.0%
3.0%
3.0%
1.0%
2.0%
3.0%
1.0%
2.0%
3.0%
1.0%
2.0%
3.0%
1.0%
2.0%
2.0%
1.0%
1.0%
LINE REGULATION
LOAD REGULATION
Note.5 1.0%
Note.6 8.0%
SETUP, RISE, HOLD UP TIME 200ms, 50ms, 16ms at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
FREQUENCY RANGE
EFFICIENCY (Typ.)
65%
70%
72%
74%
75%
78%
78%
80%
80%
82%
INPUT
AC CURRENT
1A / 100VAC
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
60A / 230VAC
0.75mA / 240VAC
150 ~ 450% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 140% rated output voltage
PROTECTION OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
IC1Tj135
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
0 ~ +40 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03% / ( 0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1950, CSA22.2, EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
I/P-O/P:3KVAC I/P-FG:1.5KVAC
SAFETY &
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022(CISPR22) class B
EMC
(Note. 7)
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,11,ENV50204, light industry level, criteria A
MTBF
500khrs min. MIL-HDBK-217F (25
)
OTHERS
DIMENSION
PACKING
PLUG
108*67*36mm (L*W*H)
0.3kg; 54pcs/ 20kg / CARTON
Standard type P2J: 2.1 * 5.5 * 11mm, center positive for stock ; Other type available by customer requested
Standard type see page2 ; Other type available by customer requested
CONNECTOR
CABLE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
NOTE
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% rated load.
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:P40A-SPEC 2008-05-08