PSPRL9802 Series
Active PFC
200 Watt Single Output
AC/DC Switching Power Supply
FEATURES
● 2 Year Warranty
● Optional Top Cover
● 90 ~ 264VAC Universal AC Input
● Approved to UL CUL TUV CE and CB
● Power Factor Corrected to EN61000-3-2 Class D
● Compact 1U Size & Power Density: 5.2 Watts/cu in.
● Providing Peak Power 600W within 500uS Duty Duration
● Convection-Cooled and with Forced Air Cooling Rating Options
● Protections: Short Circuit/ Over Load/ Over Voltage/ Over Temp
SPECIFICATIONS: PSPRL9802 Series
All specifications are based on 25oC, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
INPUT SPECIFICATIONS
Input Voltage
90 – 264VAC Full Range
Input Frequency
Input Current
47 to 63Hz
4A at 100VAC full load
Inrush Current
35A max @ 110VAC with full load and cold start.
1.5mA max @ 240VAC
Designated as REMO on the CN3, requires a low signal to inhibit output. Hiccup mode.
Leakage Current
Remote ON/OFF
OUTPUT SPECIFICATIONS
Output Voltage
See Table
Output Power Range
Output Adjustability
Total Regulation
200 Watts max.
Output user adjustable ±5% minimum.
±1%
See Table
Output Current
Ripple & Noise (peak to peak)
Transient Response
Hold-Up Time
See Table
Output voltage returns to within 1% in less than 500µs for a 50% dynamic load, peak does not excess 5%.
20ms min. at 80% of full load.
Overshoot
Turn-on/off not exceed 5% over nominal voltage.
1 second maximum at 120VAC.
Designated as RS+ and RS- on the CN3
Turn On Delay
Remote Sense
PROTECTION
Over Voltage Protection
Short Circuit Protection
Over-Temperature Protection
Over-Power Protection
Input Circuit Protection
GENERAL SPECIFICATIONS
Efficiency
Latching down will occur when output voltage exceeds 130% and recycle AC input to reset.
Trip without damage and auto-recovery.
Protected in the event of excessive operating ambient 85°C and automatic recovery.
Hiccup mode 110-140%; auto-recovery.
A protected 250V/5A fuse inserted.
70% for 3.3V, 75% for 5V, 80% for 12V, and 83% minimum for other outputs @ 230VAC and full load.
1500 VAC input line to chassis (10mA DC cut off current, isolating 3000VAC primary to secondary
windings. Primary to core 1500VAC. All for 3 seconds.
Withstand Voltage
Burn In
PFC
45 ±5°C for one hour @ 230VAC with full load.
Active power factor correction meets EN61000-3-2 class D.
Designated as PG on the CN3 will go high 100-500ms after regulation and goes low 1ms before loss of
regulation.
Power Good
Power Supply On
Grounding Test
Green LED designated as LED 1 on the PCB.
Apply 25A from ground pin of the three-prong plug to the far most earth. Max allowable resistance 0.1 ohm.