1000W Single Output with PFC Function
PSP-1000 series
Features :
Universal AC input / Full range
AC input active surge current limiting
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in constant current limiting circuit
Current sharing up to 2 units or 2000W
Built-in remote ON-OFF control
Built-in remote sense function
Built-in active current sharing and parallel function
3 years warranty
SPECIFICATION
MODEL
PSP-1000-5
PSP-1000-12
PSP-1000-13.5 PSP-1000-15
PSP-1000-24
PSP-1000-27
PSP-1000-48
DC VOLTAGE
5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK LOAD
145A
0 ~ 145A
725W
75A
67A
60A
37.6A
33.6A
19A
0 ~ 75A
900W
0 ~ 67A
904.5W
1000W
150mVp-p
12 ~ 15V
2.0%
0 ~ 60A
900W
0 ~ 37.6A
902.4W
1000W
150mVp-p
20 ~ 26.4V
1.0%
0 ~ 33.6A
907.2W
1000W
150mVp-p
24 ~ 30V
1.0%
0 ~ 19A
912W
1000W
200mVp-p
41 ~ 56V
1.0%
Note.4 800W
1000W
150mVp-p
10 ~ 13.2V
3.0%
1000W
150mVp-p
13.5 ~ 18V
2.0%
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 6.0%
OUTPUT
4.75 ~ 5.5V
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
0.5%
0.3%
0.3%
0.3%
0.2%
0.2%
0.2%
2.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1500ms, 50ms/230VAC
1500ms, 50ms/115VAC at full load
24ms/230VAC
Note.6 90 ~ 264VAC
47 ~ 63Hz
24ms/115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
0.96/230VAC
77%
0.96/115VAC at full load
84% 84%
5.6A/230VAC
63A/230VAC
INPUT
84%
85%
86%
86%
11.2A/115AVC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
32A/115VAC
<2mA / 240VAC
115 ~ 140% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V 27.6 ~ 32.4V 31 ~ 36.5V
Protection type : Shut down o/p voltage, re-power on to recover
95 (TSW1) detect on the heatsink of PFC MOSFET 90 (TSW2) detect the winding of output choke
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
OVERLOAD
57.6 ~ 67.2V
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
RC+/RC-: 0 ~ 0.8V=power on ; 4 ~ 10V=power off
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
sink current <20mA
FUNCTION REMOTE CONTROL
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
TEMP. COEFFICIENT
VIBRATION
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY &
EMC
(Note 5)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
59.6K hrs min. MIL-HDBK-217F (25
278*129*127mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
5.2Kg; 3pcs/16.3Kg/1.42CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 10% Duty cycle maximum within every 30 seconds(max.). Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:PSP-1000-SPEC 2008-06-30