PSMSC60 SERIES
60 Watts
Medical AC/DC Power Module
Single Output
Rev C
FEATURES
• Universal Input Range of
90~264VAC
• Over Current, Over Voltage, and Short Circuit
Protection
• Switching Power Modules for PCB • Isolation Class II
Mounting
• Fully Encapsulated Plastic Case
• Regulated Outputs
• CE, CB, UL, and cUL Safety Approvals
DESCRIPTION
The PSMSC60 series of medical AC/DC power modules offers up to 60 watts of output
power in a fully encapsulated 3.50” x 2.5” x 1.06” plastic case. This series consists of
regulated single output models with a universal input range of 90~264VAC. Each model
in this series features over current, over voltage, and short circuit protection, isolation
class II and CE, CB, UL, and cUL safety approvals. Please call factory for order details.
Size: 3.50in x 2.5in x 1.06in (89mm x 63.5mm x 27mm)
Input Voltage
MODEL SELECTION TABLE
Max. Ripple &
Noise(2)
Maximum
Capacitive Load
No Load
Input Power
Model Number
Output Voltage Output Current
Efficiency
Output Power
Range
PSMSC60-5S
PSMSC60-9S
PSMSC60-12S
PSMSC60-15S
PSMSC60-24S
5.1VDC
9VDC
12VDC
15VDC
24VDC
10,000mA
6666mA
5000mA
4000mA
2500mA
100mVp-p
100mVp-p
1% of Vout
1% of Vout
1% of Vout
10000µF
5000µF
5000µF
4000µF
2000µF
86%
87%
88%
86%
87%
51W
60W
60W
60W
60W
90~264VAC
(120~370VDC)
<0.3W
SPECIFICATIONS
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Typ
Max
Unit
INPUT SPECIFICATIONS
90
120
47
264
370
440
1.5
1
VAC
VDC
Hz
Input Voltage Range
Frequency
Full Load, 115VAC
Full Load, 230VAC
@115VAC
Input Current
A
A
55
95
Inrush Current (<2ms, Cold Start)
@230VAC
Leakage Current
@264VAC (Touch Current)
Slow Blow Type
0.1
mA
A
External Fuse (Recommended)
OUTPUT SPECIFICATIONS
Output Voltage
3.15
See Table
Voltage Accuracy
Line Regulation
±2
0.5
1.5
1
%
%
5V & 9V Models
12V, 15V, & 24V Models
Load Regulation
1-100%
%
Output Power
See Table
Output Current
See Table
See Table
See Table
Maximum Capacitive Load
@230VAC
Ripple & Noise(2)
Hold-Up Time
10
mS.
Temperature Coefficient
PROTECTION
±0.05
%/ºC
Short Circuit Protection
Over Current Protection
Over Voltage Protection
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Automatic Recovery
Automatic Recovery
Zener Diode Clamp
With Derating
-40
-40
+80
+90
ºC
ºC
Under 115VAC
Others
73
80
Max. Case Operating Temperature
ºC
Altitude
Humidity
Atmospheric Pressure
MTBF
During Operation
5000
95
m
%RH
kPa
70
200,000
106
400,000
@25ºC
Hours
Wall Industries, Inc. • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
website: www.wallindustries.com • e-mail: sales@wallindustries.com
11/22/2019
Page 1 of 4