PSC 600 Series
2 5 0 - 8 0 0 W A T T S D C / D C S I N G L E O U T P U T
Features
•
•
•
•
•
Single outputs from 5Vdc to 125Vdc.
Conformal coating.
Under voltage alarm.
High efficiency.
Operating temperature range -25°C to +70°C with
no derating.
•
•
Fully encapsulated, IP30 as standard.
Convection cooled.
ENVIRONMENTAL
Specifications
INPUT
Operating temperature
-25°C to 70°C
(100% load, single output >10Vdc).
-25°C to +55°C
(100% load, single output <10Vdc).
Voltage
See Table
Isolation
Input - Output: 2.5kVac / 4kVdc
Input – Case: 2.5kVac / 4kVdc
Output– Case, all outputs: 2kVdc
Temperature coefficient
Storage temperature
GENERAL
0.02%/°C.
Reverse input voltage
protection
Parallel diode (Input code: 24, 48)
Series diode (Input code: 110, 220)
-40°C to 85°C.
OUTPUT
Cooling
Convectional cooling.
Voltage
See table.
See table.
0.2%.
-Built in series diode – C.
-Remote sense – S.
Current
Optional Features
-Inrush current limit. On input code 24 and 48
the inrush limit circuit is optional. This option
affects the input voltage range. The circuit is
always active thus acting at voltage dips below
the stop level > 10ms.
-2.5kVac isolation input/case –E1.On the 24
and 48 inputs.The emission level increases to level
A.
-2.5kVac isolation output/case
-E2.The emission level increases to level A.
-Euro panel –L,10TE OR 14TE
-Wall mounting panels –N. Included H15
connector holder. Standard female Connector
H15-T. To mount on a DIN TS-35 rail, we can
supply optional DIN rail clips.
Source regulation
Load regulation
Output ripple (50kHz)
0.2%.
20mV p-p typ.
Input ripple attenuation on 150:1
output 50 to 400Hz
Voltage adjustment
Current limit protection
Overvoltage protection
Under voltage alarm
Remote sense
90% - 110%.
105%.
115%.
90% of nominal output.
Option S.
Yes.
Soft start
-Wider input range The PSC600 series can be
supplied with wide input range to meet train or
mobile application demands.
Start-up time
1s
Hold-up time
2-25ms
80 - 93%
50 kHz
STANDARDS
Safety
Efficiency
IEC60950
Switching Frequency
EMI standards
C-Tick
EN55011/EN55022 class B, EN61000-6-3
AS/NZS CISPR11: 2002 Group1 Class A
EN61000-6-2, EN/IEC61000-4-4, EN61000-4-5
Selection Table
EMC standards
Note:
T-input range for mobile application
Uin 0.1s-S2
14.4-33.6V
21.6-50.4V
28.8-67.2V
43.2-110.8V
66-154V
Continuous range
16.8-30V
Code
24T
For mechanical dimensions and mounting options please contact Powerbox for
further details.
25.2-45V
36T
33.6-60V
48T
50.4-90V
72T
77-137.5V
110T
The total output power can be derated on a T-range compared with the above
output rating table. Input according to EN50155:2001 and IEC90571:1998
422