PSAK450 SERIES
Rev B
Wall Industries, Inc.
Up to 457 Watts, AC/DC Switching Power Supplies
FEATURES
• RoHS Compliant
• High Efficiency up to 93%
• Built-in Active PFC, PF > 0.90
• Up to 457 Watts Output Power
• +5V/0.3A Auxiliary Output
• 150% Peak Load Capability
• Power OK Signal
• 3000VAC (4242VDC) I/O Isolation
• Remote ON/OFF, Remote Sense Functions
• Universal Input Voltage Range: 90~264VAC (127~370VDC)
• Protection: SCP / OLP / OVP / OTP / Fan Failure
• 12V, 24V, 30V, 36V, & 48VDC Single Output Models
• UL 60950-1 and EN60950-1 Safety Approvals
• Constant Current Limit
DESCRIPTION
The PSAK450 series of AC/DC switching power supplies provides up to 457 Watts of output power
in a 7.835” x 4.134” x 1.614” enclosed case. This series consists of single output models ranging
from 12VDC to 48VDC with an input voltage range of 90~264VAC (127~370VDC). Standard
features include high efficiency up to 93%, active PFC, remote on/off, remote sense, and power
OK signal. This series also has short circuit, over load, over voltage, and over temperature
protection. All models are RoHS compliant and have UL 60950-1 and EN60950-1 safety approvals.
Size:
7.835 x 4.134 x 1.614 inches
199.0 x 105.0 x 41.0 mm
Weight:
2.43 lbs (1.1kg)
MODEL SELECTION TABLE
Model Number Input Voltage (2) Output Voltage Output Current Over Voltage Protection Output Power Ripple & Noise (1) Efficiency
PSAK-450-12
PSAK-450-24
PSAK-450-30
PSAK-450-36
PSAK-450-48
NOTES
12 VDC
24 VDC
30 VDC
36 VDC
48 VDC
37.5A
19A
14.4 ~ 15.6 VDC
28.8 ~ 31.2 VDC
36.0 ~ 39.0 VDC
43.2 ~ 46.8 VDC
57.8 ~ 62.4 VDC
450W
456W
450W
457W
456W
120mVp-p
240mVp-p
300mVp-p
360mVp-p
480mVp-p
89%
91%
91%
92%
93%
90 ~ 264 VAC
15A
(127 ~ 370 VDC)
12.7A
9.5A
1. Ripple & noise is measured at 20MHz limited bandwidth and using a 12" twisted pair-wire terminated with a 0.1µF & 47µF capacitors in parallel.
2. For voltages near the low end of the input voltage range, see the derating curve for the power supply output rating.
3. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still
meets EMC directives.
DERATING CURVES
Load vs Ambient Temperature
Load vs Input Voltage
Ta=25°C
100
90
80
70
60
50
40
100
80
60
40
20
-20
0
10
20
30
40
50
60
70
90
264
100
110
120
Ambient Temperature (°C)
Input Voltage (VAC)
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com