65W Single Output Switching Power Supply
PS-65 series
Features :
Universal AC input/Full range
Low leakage current<0.5mA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
SPECIFICATION
MODEL
PS-65-3.3
PS-65-5
PS-65-7.5
PS-65-12
PS-65-13.5 PS-65-15
PS-65-24
PS-65-27
PS-65-48
DC VOLTAGE
3.3V
5V
7.5V
8A
12V
13.5V
4.7A
15V
24V
27V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
12A
12A
5.2A
4.2A
2.7A
2.4A
1.35A
0 ~ 1.5A
64.8W
0 ~ 15.2A
39.6W
0 ~ 13.8A
60W
0 ~ 9.6A
60W
0 ~ 6A
62.4W
0 ~ 5.4A
63.5W
0 ~ 4.8A
63W
0 ~ 3A
64.8W
0 ~ 2.7A
64.8W
OUTPUT POWER (max.)
Rated output power for convection; 72W (+3.3V : 50W;+5V:69W) with 18 CFM min. Forced air
100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 3.0%
100mVp-p
100mVp-p
OUTPUT
3.14 ~ 3.63V 4.75 ~ 5.5V 7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.25 ~ 16.5V 22.8 ~ 26.4V 25.65 ~ 29.7V 45.6 ~ 52.8V
3.0%
1.0%
3.0%
3.0%
1.0%
3.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
1.0%
3.0%
800ms, 20ms at full load
60ms at full load
90 ~ 264VAC
47 ~ 440Hz
69%
127 ~370VDC
FREQUENCY RANGE
EFFICIENCY(Typ.)
76%
79%
79%
79%
79%
80%
80%
80%
INPUT
1.2A/115VAC
0.72A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
COLD START 20A/115VAC
<0.75mA / 240VAC
40A/230VAC
LEAKAGE CURRENT
OVERLOAD
73 ~ 105W(3.3V : 51 ~ 75W)(5V : 70 ~ 105W) rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
PROTECTION
ENVIRONMENT
SAFETY &
3.8 ~ 4.46V 5.75 ~ 6.75V 8.63 ~ 10.1V 13.8 ~ 16.2V 15.5 ~ 18.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 31 ~ 36.45V 55.2 ~ 64.8V
OVER VOLTAGE
WORKING TEMP.
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
0.04%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
EMC
(Note 4)
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
MTBF
300.7K hrs min. MIL-HDBK-217F (25
127*76*42mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
0.21Kg; 54pcs/14.2Kg/1.35CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
File Name:PS-65-SPEC 2007-03-14