Specificaꢀons
Safety Standards & EMC Specificaꢀons
UL ES 60601-1, CSA C22.2 No. 60601-1 File No. E178020
TÜV EN 60601-1
Safety Standard Approvals
EMI Standard
EN55011, FCC & VCCI Class B conducted and radiated
EN61000-3-2: Harmonic distorꢀon, class A and D
EN61000-3-3: Line flicker
EN61000-4-2: ESD, ±15 KV air and ±8 KV contact
EN61000-4-3: Radiated immunity, 10 V/m
EN61000-4-4: Fast transient/burst, ±2 KV
EN61000-4-5: Surge, ±1 KV diff., ±2 KV com
EN61000-4-6: Conducted immunity, 10 Vrms
EN61000-4-8: Magneꢀc field immunity, 30 A/m
EN61000-4-11: Voltage dip immunity, 30% reducꢀon for 500 ms,
100% reducꢀon for 10 ms
EMC Performance
*Consult with TT Electronics for informaꢀon on addiꢀonal country safety approvals
Input Specificaꢀons
Input Voltage Range
Input Frequency Range
Input Current
90-264 VAC
47 to 63Hz
1.4 A (rms) for 115 VAC, 0.7 A (rms) for 230 VAC
200 μA max. @ 264 VAC, 63Hz
100 μA max. @ 264 VAC, 63Hz
>0.9
Earth Leakage Current
Touch Current
Power Factor
Output Specificaꢀons
Ripple and Noise
1% peak to peak maximum at the full load
Provided and set at 115-140% of its nominal output voltage
Protected to short circuit condiꢀons
Overvoltage Protecꢀon
Overcurrent Protecꢀon
Temperature Coefficient
±0.04% /°C maximum
Maximum excursion of 4% or beꢁer on all models, recovering to 1%
of final value within 500 us aꢂer a 25% step load change
Transient Response
Environmental Specificaꢀons
Operaꢀng Temperature
Storage Temperature
Relaꢀve Humidity
0°C to +60°C (See Deraꢀng)
-40°C to +85°C
5% to 95% non-condensing
Temperature deraꢀng
Derate from 100% at +40°C linearly to 50% at +60°C
General Specificaꢀons
Switching Frequency
Power Factor
Efficiency
70-140KHz
0.98 Typical at 115 VAC
87% min. at full load
Hold-up Time
Line Regulaꢀon
Inrush Current
10ms minimum at 110 VAC
±0.5% maximum at full load
80 A @ 115 VAC or 120 A @ 230 VAC, at 25℃ cold start
5600 VDC from input to output (2 MOPP)
2100 VDC from input to ground (1 MOPP)
700 VDC from output to ground
Withstand Voltage
(To verify AC strength, get correct test method to avoid power sup-
ply damage.)
For Class II models, 4000 VAC from input to output
150,000 hours at full load at 25℃ ambient, calculated per MIL-HDBK
MTBF
General Note
TT Electronics | Power Partners, Inc
-217F
All data sheets are subject to change without noꢀce.
43 Broad Street Suite B206, Hudson, MA 01749, USA. t: +1 (978) 567-9600
ISS.2 14/07/2020 Page: 2