Features:
•
•
•
•
•
•
•
•
•
BF Class insulaꢀon
Medical and ITE approvals
Compact size 2 ” x 4” x 1.18”
Single, dual and triple outputs
Wide-range input 90-264 VAC
Low earth leakage current
Level B emissions
RoHS compliant
Suitable for both Class I and Class II applicaꢀons*
Descripꢀon:
The PM60 series of compact, open PCB constructed, AC-DC switching power supplies are capable of delivering 37.5-64 waꢁs
of conꢀnuous output power at convecꢀon cooling. They operate at 90-264 VAC input voltage without the need of voltage
selecꢀon, and are suited for medical, informaꢀon technology and industrial applicaꢀons. Approval to both EN60601-1 and
EN60950-1 safety standards improves design-in ꢀme and reduces end equipment compliance costs.
Output #1
Output #2
Min. Max.
Current Current
Output #3
Min. Max.
Current Current
Max.
Output
Power
Model1
Min.
Max. Current Max. Current
Current at convecꢀon
V1
5V
Tol.
±2%
±2%
±2%
±2%
±2%
±3%
±3%
±3%
V2
Tol.
V3
Tol.
At 5 CFM2
PM60-10A
PM60-12A
PM60-13A
PM60-14A
PM60-18A
PM60-23A
PM60-25A
PM60-31A
0A
0A
11A
5A
11A
N/A
N/A
55W
60W
64W
64W
64W
55W
55W
55W
37.5W
12V
15V
24V
48V
5V
5A
4.3A
2.7A
11A
8A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0A
4.3A
2.7A
1.35A
6A
0A
0A
0.5A
0.5A
0.5A
0.5A
0.5A
0.5A
0.5A
12V
24V
12V
0.1A
0.1A
0.1A
0.1A
0A
3A
1.5A
3A
±5%
±5%
5V
6A
8A
5V
6A
8A
±5% -12V
±5% 12V
±5% 12V
±5% -15V
±5% -12V
0A
0A
0A
0A
0A
0.5A
0.5A
0.5A
0.5A
0.5A
±4%
±4%
±4%
±4%
±4%
PM60-31-3A 3.3V
6A
8A
±3% 5.2V
±3% 3.3V
3A
37.5W/
47.5 W
PM60-31-5A
PM60-32A
5V
5V
5V
6A
8A
1.5A
2.4A
1.5A
6A
8A
±3%
±3%
15V
24V
0.1A
0.1A
55W
55W
PM60-39A
6A
8A
Notes:
1. Safety approvals are for PCB form only. To order unit with cover fiꢁed, change suffix “A” to “C”.
2. Maximum current of output #1 of mulꢀ-output models can be 8 A at 5 CFM forced air provided by user.
3. PM60-31-5A is rated at 37.5 W maximum at convecꢀon cooling or 47.5 W maximum at 5 CFM forced air cooling by user.
4. The output voltages of a mulꢀple output model may go outside of the stated tolerance when an output load current is out of stated limits. All mod-
els may be operated at no-load without damage.
5. Ripple and noise is maximum peak to peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges,
and with a 10 μF tantalum capacitor in parallel with a 0.1 μF ceramic capacitor across the output.
TT Electronics | Power Partners, Inc
General Note
43 Broad Street Suite B206, Hudson, MA 01749, USA. t: +1 (978) 567-9600
All data sheets are subject to change without noꢀce.
SL-xxx-xxx ISS.6 22/07/2020 Page: 1
© TT Electronics plc