30W Single Output LED Power Supply
PLC-30 series
Features :
Universal AC input / Full range
Adjustable output voltage and current level
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Built-in constant current limiting circuit
Fully isolated plastic case with terminal block style of I/O
Built-in active PFC function, comply with EN61000-3-2 class C
(Pin 25W)
Class
power unit, no FG
Class 2 power unit
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications (Note.2)
Compliance to worldwide safety regulations for lighting
2 years warranty
110
F
M
M
SELV
( for 48V only)
( except for 48V )
SPECIFICATION
MODEL
PLC-30-9
PLC-30-12
PLC-30-15
PLC-30-20
PLC-30-24
PLC-30-27
PLC-30-36
PLC-30-48
DC VOLTAGE
9V
12V
15V
20V
24V
27V
36V
48V
CONSTANT CURRENT REGION Note.6 6.3 ~ 9V
8.4 ~ 12V
2.5A
10.5 ~ 15V
2A
14 ~ 20V
1.5A
16.8 ~ 24V
1.25A
18.9 ~ 27V
1.12A
25.2 ~ 36V
0.84A
33.6 ~ 48V
0.63A
RATED CURRENT
CURRENT RANGE
RATED POWER
3.3A
0 ~ 3.3A
29.7W
0 ~ 2.5A
30W
0 ~ 2A
30W
0 ~ 1.5A
30W
0 ~ 1.25A
30W
0 ~ 1.12A
30.24W
2.3Vp-p
0 ~ 0.84A
30.24W
3.6Vp-p
0 ~ 0.63A
30.24W
3.7Vp-p
45.6 ~ 52.8V
RIPPLE & NOISE (max.) Note.2 2.6Vp-p
VOLTAGE ADJ. RANGE Note.5 8.55 ~ 9.9V
2Vp-p
2.6Vp-p
2.6Vp-p
2.4Vp-p
OUTPUT
11.4 ~ 13.2V
14.5 ~ 16.5V 19 ~ 22V
22.8 ~ 26.4V 25.65 ~ 29.7V 34.2 ~ 39.6V
CURRENT ADJ. RANGE Note.5 2.475 ~ 3.399A 1.875 ~ 2.575A 1.5 ~ 2.06A
VOLTAGE TOLERANCE Note.3 10%
1.125 ~ 1.545A 0.938 ~ 1.288A 0.84 ~ 1.1536A 0.63 ~ 0.865A 0.473 ~ 0.649A
LINE REGULATION
LOAD REGULATION
SETUP TIME
3.0%
5.0%
2000ms / 230VAC 3000ms / 115VAC at full load
VOLTAGE RANGE
Note.4 90 ~ 264VAC
47 ~ 63Hz
PF>0.95/115VAC, PF>0.9/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
LEAKAGE CURRENT
INPUT
80%
82.5%
83.5%
84%
84%
84.5%
85%
85.5%
0.4A/115VAC 0.2A/230VAC
40A/230VAC
<0.5mA / 240VAC
100 ~ 110%
OVER CURRENT
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
SHORT CIRCUIT
OVER VOLTAGE
10 ~ 14V
Protection type : Shut down o/p voltage, re-power on to recover
95 10 (TSW1)
14 ~ 16V
17 ~ 22V
23 ~ 26V
27 ~ 34V
31 ~ 35V
40 ~ 50V
53 ~ 63V
PROTECTION
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +50 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +80 , 10 ~ 95% RH
ENVIRONMENT
0.06%/ (0 ~ 50
)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
UL1310, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), J61347-1, J61347-2-13 approved
I/P-O/P:3.75KVAC
SAFETY &
EMC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C (Pin 25W), Class D (>70% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level, criteria B
EMC IMMUNITY
MTBF
625.5Khrs min. MIL-HDBK-217F (25
160*46*30mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.2Kg; 70pcs/15Kg/0.96CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB.
6. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:PLC-30-SPEC 2012-03-12