19013 36th Ave. West Suite H Lynnwood, WA 98036, USA
PEV PECL VCXO Series
6 Pad Leadless Surface Mount PECL Voltage Controlled Xtal Oscillator
–
100.00 MHz 650.00 MHz
Differential PECL Output with Enable/Disable
Consult factory for higher frequencies
Standard Specifications
Overall Frequency Stability
Operating Temperature Range
Supply Voltage (Vcc)
± 50, 25, 20 PPM over Operating Temperature Range
-
°
0 to +70 C is standard, but can be extended to 40 to +85°C for certain frequencies
3.3 volts ± 10% standard, but 5.0 volts or 2.5 volts also available
50 mA typical, 75 mA maximum
Supply Current (Icc)
Jitter
Output Load
Enable/Disable Option (E/D)
6 pS RMS maximum, from 12 kHz to 20 MHz from carrier
Output must be terminated into 50 ohms to (Vcc - 2.0 V). See Test Circuit 10 and Note 1.
Output enabled when Pin #2 is open or at CMOS Logic “1”;
Output disabled when Pin #2 is at CMOS Logic “0”.
Control Voltage Range (CVR)
Pullablity over CVR
Linearity
0.5 to 4.5 volts: 5.0 V Supply; 0.33 to 2.97 volts: 3.3 V Supply; 0.25 to 2.25 volts: 2.5 V Supply
± 100 PPM. Consult factory for > 100 PPM.
± 20% (Consult factory for ± 10%)
Symmetry
Tr & Tf
Logic “1”
45/55% to 55/45% at 50% of Vcc level (see Waveform 2)
1.0 nS max (20 to 80%)
Vcc - 1.025 volts minimum
Output Waveform
PECL with Differential Output
Logic “0”
Vcc - 1.620 volts maximum
Note 1: In the typical PECL 100K logic output Voh is 2.35 volts and Vol is 1.60 volts at 3.3 Vcc. The center voltage of the PECL is therefore1.975 volts.
If a 50 resistor is placed between the output and Vcc – 2 volts (1.3 volts), the current through the resistor is (1.975 – 1.3) / 50 = 13.5 mA.
W
±
The same load can be simulated by a resistor of 147 1% ohms to ground (1.975 / 0.0135 = 146.29 ohms). If additional load current is placed
on the output, its load current must be subtracted from the 13.5 mA to calculate a new load resistor. Using similar calculations, use 274 ± 1%
ohms to ground for 5.0V operation.
Part Numbering Guide
3 PEV 20 B W - 100.0M
Packaging
Tube or
Supply Voltage
Frequency in MHz
24mm tape
16mm pitch
Blank= 5.0 volts ±10%
3= 3.3 volts ±10%
2= 2.5 volts ±5%
Frequency Deviation (Pullability) over CVR
W: ± 100 PPM
Model
Frequency Stability
Operating Temperature Range
20 = ± 20 PPM
25 = ± 25 PPM
50 = ± 50 PPM
B: 0 to +70°C
F: - 40 to +85°C
Consult factory for available frequencies and specs. Not all options available for all frequencies. A special part number may be assigned.
Frequency Stability is inclusive of frequency shifts due to calibration, temperature, supply voltage, shock, vibration and load
inches (mm)
Mechanical:
not to scale
Solder Pads
Due to part size and factory abilities, part marking may vary from lot to lot and may contain our part number or an internal code.
Vcc
Q
QN
6
5
4
4
5
6
PLE
.05
(1.3)
1
3
2
1
2
3
GND E/D Vcon
.560 (14.23) MAX
.217 (5.5)
MAX
.200 (5.08)
Consult factory for optional 'J' leads
May 2002
(425) 776 -1880, Fax: (425) 776-2760, ple-sales@pletronics.com, www.pletronics.com
4
Pl tronics, Inc.