导电性高分子固体铝电解电容器(标准品)-引线型
Conductive polymer solid aluminum electrolytic capacitor (Standard product)- Radial type
PE
特点 Features
可适于无铅焊。
Lead free-fiow is supported.
RoHS指令已对应完毕。Adapted to the RoHS directive.
主要技术性能 Specifications
项目 Items
特性 Characteristics
-55~+105℃
工作温度范围
Operating Temperature Range
额定电压范围
2.5~25V
6.8~3300μF
Rated Voltage Range
标称电容量范围
Nominal Capacitance Range
标称电容量允许偏差
Nominal Capacitance Tolerance
±20%(20℃,120Hz)
漏电流
Leakage Current
参照规格表 Reference parameter table
2分钟 at 20℃, after 2 minutes
损耗角正切(tgδ)
Dissipation Factor (Max)
直径
tgδ
Φ5~Φ5.45
0.10
Φ6.3(L≦7)
0.10
Φ6.3 (L>7)
0.08
Φ8~Φ10
0.08
20℃, 120Hz
等效串联电阻 ESR
参照规格表 Reference parameter table (mΩ at 100k~300kHz 20℃ max)
高低温特性比
Characteristics of impedance
ratio at high temp. and low temp
-55℃
Z/Z20℃
Z/Z20℃
5 to 1.25
0.75 to 1.25
要求在100KHZ 20℃
Based the value at 100KHZ. +20℃
+105℃
+105℃施加额定电压2000小时后,待温度恢复到20℃后进行测试,电容器应满足以下要求:
After 2000 hours’ application of rated voltage at 105℃, and then being stabilized at +20℃, the capacitors shall meet the following requirement:
电容量变化率
Capacitance Change
±20%初始值以内
Within ±20% of the initial value (16V: within ±25% of the initial value)
耐久性
Load Life
损耗角正切
Dissipation Factor
≤ 150%初始规定值
Not more than 150% of the initial specified value
阻抗
≤ 150%初始规定值
Not more than 150% of the initial specified value
Equivalent Series Resistance
漏电流
Leakage Current
≤初始规定值
Not more than the initial specified value
60℃, 90~95% RH, 不加电压1000小时 60℃ , 90~95% RH, 1000 hours, No-applied voltage.
电容量变化率
Capacitance Change
±20%初始值以内
Within ±20% of the initial value (16V: within ±25% of the initial value)
稳态湿热
Damp heat(Steady state)
损耗角正切
Dissipation Factor
≤150%初始规定值
Not more than 150% of the initial specified value
阻抗
≤150%初始规定值
Not more than 150% of the initial specified value
Equivalent Series Resistance
漏电流
Leakage Current
≤初始规定值
Not more than the initial specified value
(VPS)(260℃ X 10s)
电容量变化率
Capacitance Change
±10%初始值以内
Within ±10% of the initial value (16V以上: within ±15% of the initial value)
耐焊接热
Resistance to Soldering Heat
损耗角正切
Dissipation Factor
≤初始规定值
Not more than the initial specified value
阻抗
≤初始规定值
Not more than the initial specified value
Equivalent Series Resistance
漏电流
Leakage Current
≤初始规定值
Not more than the initial specified value
※ 当产生疑问的时候,用以下电压处理后测定。
电压处理: 125℃下,连续加载120 分钟的电压。加载电压为额定电压。
When in doubt, apply the following voltage treatment and measure.
Voltage processing: under the condition of 125 ℃ ambient temperature, continuous load voltage of 120 minutes. Load voltage is rated voltage.
目录中记载的内容可能未经提示而变更。贵司在购买时请要求提供承认书,并以此为基准使用。
The contents recorded in the catalogue might be changed without any reminder.Please ask for providing the datasheet and take it as standard when purchasing.
031