品牌 Logo 应用领域
XPPOWER /
页数 文件大小 规格书
4页 307K
描述
AC-DC Power Supplies

PCM80PD03 数据手册

 浏览型号PCM80PD03的Datasheet PDF文件第2页浏览型号PCM80PD03的Datasheet PDF文件第3页浏览型号PCM80PD03的Datasheet PDF文件第4页 
50/80/120 Watts  
PCM Series  
xppower.com  
4000 VAC Isloation  
Low Leakage Current  
Single, Dual and Triple Outputs  
Worldwide Medical Approvals  
CCC Approved (PCM80)  
Both Line and Neutral Fused  
Non-standard Connectors Available  
Specification  
Input  
General  
Efficiency  
• Single output models: 80ꢀ typical  
Multi output models: 75ꢀ typical  
Input Voltage  
Input Frequency  
Input Current  
• 90-264 VAC  
• 47-63 Hz  
Isolation  
• 4000 VAC Input to Output  
1500 VAC Input to Ground  
500 VAC Output to Ground  
• PCM50:  
PCM80:  
1.35 A max  
1.30 A max  
PCM120: 1.60 A max  
Switching Frequency  
• PCM50: 64 kHz typical  
PCM80: 55 kHz typical  
PCM120: 120 kHz typical  
Inrush Current  
Power Factor  
• 30 A at 115 VAC or  
60 A at 230 VAC at 25 ˚C cold start  
• PCM50: 0.55 typical  
PCM80/120: 0.94 min  
MTBF  
• 100 kHrs at full load and 25 ˚C ambient  
per MIL-HDBK-217F  
Earth Leakage Current • 180 µA max at 132 VAC/60Hz  
300 µA max at 264 VAC/50Hz  
Environmental  
Output  
Operating Temperature • PCM50: 0 ˚C to +70 ˚C, derate from 100ꢀ  
load at 50 ˚C to 50ꢀ load at +70 ˚C  
Output Voltage  
Minimum Load  
• See tables  
PCM80: 0 ˚C to +70 ˚C, derate from 100ꢀ  
load at 40 ˚C to 50ꢀ load at +70 ˚C  
PCM120: 0 ˚C to +60 ˚C, derate from  
• No minimum load required for single  
output models. See tables for multi  
output models  
100ꢀ load at 40 ˚C to 50ꢀ load at +60 ˚C  
Start Up Delay  
Hold Up Time  
Line Regulation  
• 2 s max  
Storage Temperature  
• PCM50/80: -40 ˚C to +80 ˚C  
PCM120: -20 ˚C to +85 ˚C  
• 10 ms min at low line  
1ꢀ max at full load for 10ꢀ cꢁange  
in input  
EMC & Safety  
Load Regulation  
5ꢀ max  
Emissions  
• EN55022, level B conducted  
EN55022, level B radiated  
Transient Response  
• 5ꢀ max. deviation, 500 µs recovery time  
for a 50ꢀ load cꢁange  
Harmonic Currents  
Voltage Flicker  
ESD Immunity  
• EN61000-3-2, class A  
Ripple & Noise  
• 2ꢀ pk-pk, 20MHz BW  
• EN61000-3-3 amendments 1 & 2  
Overvoltage Protection • 112-132ꢀ witꢁ auto recovery on V1  
• IEC61000-4-2, level 3  
Perf Criteria B  
Overcurrent Protection • 110-200ꢀ witꢁ auto recovery  
on all outputs  
Radiated Immunity  
EFT/Burst  
• IEC61000-4-3 10 V/m, level 3  
Perf Criteria B  
Temperature  
Coefficient  
0.05ꢀ /˚C  
• IEC61000-4-4, level 3  
Perf Criteria B  
Surge  
• IEC61000-4-5, level 3  
Perf Criteria B  
Conducted Immunity  
• IEC61000-4-6 10 V/m, level 3  
Perf Criteria B  
Power Frequency  
Magnetic Fields  
• IEC61000-4-8 10 A/m, Perf Criteria B  
Dips & Interruptions  
• IEC61000-4-11, 30ꢀ 500 ms,  
60ꢀ 100 ms, 100 ꢀ 5000 ms  
Perf Criteria A, A, C  
Safety Approvals  
• UL60601-1, CSA C22.2 No. 601.1 per cUL  
EN60601-1, CCC (PCM80)  

与PCM80PD03相关器件

型号 品牌 获取价格 描述 数据表
PCM80PD04 XPPOWER

获取价格

AC-DC Power Supplies
PCM80PD05 XPPOWER

获取价格

AC-DC Power Supplies
PCM80PD06 XPPOWER

获取价格

AC-DC Power Supplies
PCM80PD07 XPPOWER

获取价格

AC-DC Power Supplies
PCM80PD08 XPPOWER

获取价格

AC-DC Power Supplies
PCM80PS05 XPPOWER

获取价格

AC-DC Power Supplies
PCM80PS07 XPPOWER

获取价格

AC-DC Power Supplies
PCM80PS09 XPPOWER

获取价格

AC-DC Power Supplies
PCM80PS10 XPPOWER

获取价格

AC-DC Power Supplies
PCM80PS12 XPPOWER

获取价格

AC-DC Power Supplies