Catalog 1308242
Issued 3-03 (PDF Rev. 3-04)
OEG
PCL/PCLH series
3A, 5A, 10A, 15A General Purpose
Miniature Relay
Factory Autom ation, Process Controls,
Electrical Panels, etc.
UL File No. E58304
CSA File No. LR48471
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
Coil Data@ 20°C
• Small size, 3A, 5A, 10A and 15A switching capacity.
• Meets UL and CSA requirements.
• 1 pole, 2 poles and 4 poles contact arrangements.
• AC and DC coils with UL Class F (155°C) coil insulation system standard.
• Optional flange mount case.
PCL AC Coil
Must Operate
Voltage
Coil
Resistance
(ohms)±10%
Must Release
Voltage
Nom inal Coil
Pow er
Rated Coil
Voltage
(VAC)
(VAC)
(VAC)
(VA)
6
12
10
40
• Plug-in terminals or PCB terminals.
24
48
160
600
Contact Data @ 20°C
80% max.
30% min.
abt. 1.4
100
110/120
200
2,800
3,400
11,000
13,600
Arrangem ents: 1 Form A (SPST-NO),
2 Form A (DPST-NO),
4 Form A (4PST-NO),
Material: Ag, Ag Alloy.
1 Form C (SPDT),
2 Form C (DPDT),
4 Form C (4PDT).
220/240
Max.Sw itching Rate: 300ops./min.(Mechanical).
30ops./min.(Electrical).
Expected Mechanical Life: 100 million operations (no load).
Expected Electrical Life: 100,000 operations (rated load).
Minim um Load: 100mA @ 5VDC.
PCL DC Coil
Rated Coil
Voltage
(VDC)
Coil
Resistance
(ohms)±10%
Must Operate
Voltage
Must Release Nom inal Coil
Voltage
(VDC)
Pow er
(W)
(VDC)
6
12
24
40
160
650
2,600
11,000
Initial Contact Resistance: 50milliohms @ DC6V,1A.
abt. 0.9
abt. 1.1
80% max.
10% min.
Contact Ratings
48
100/110
Ratings: PCL-4
3A @ AC250V/DC24V resistive.
5A @ AC250V/DC24V resistive.
PCL-2
PCLH-2 15A @ AC120V resistive.
10A @ AC250V/DC24V resistive.
PCLH-1 15A @ AC250V/DC24V resistive.
Max. Sw itched Current: PCL-4
3A.
PCL-2
5A.
PCLH-2
PCLH-1
15A.
15A.
Operate Data @ 20°C
Must Operate Voltage: AC 80% of nominal voltage or less.
DC 80% of nominal voltage or less.
Must Release Voltage: AC 30% of nominal voltage or more.
DC 10% of nominal voltage or more.
Operate Tim e: AC 20ms max.
Max. Sw itched Pow er: PCL-4
660VA, 72W.
1,100VA, 120W.
3,168VA, 240W.
3,300VA, 360W.
PCL-2
PCLH-2
PCLH-1
DC 15ms max.
Release Tim e: AC 20ms max.
Initial Dielectric Strength
Betw een Open Contacts: 1,000VAC 1minute.
DC 8ms max.
Betw een Adjacent Contact Term inals: 1,500VAC 1minute.
Betw een Contacts and Coil: 2,000VAC 1minute.
Surge Voltage (Coil-Contact): 3,000V(1.2/50µs).
Environm ental Data
Tem perature Range:
Operating: -10°C to +55°C.
Initial Insulation Resistance
Hum idity: 45 to 85% . (Non-condensing).
Vibration, Operational: 10 to 55Hz 1.0mm double amplitude.
Mechanical: 10 to 55Hz 1.0mm double amplitude.
Shock, Operational: 100m/s2 (abt. 10G).
Mechanical: 1,000m/s2 (abt. 100G).
Betw een Open Contacts: 1,000Mohms @ 500VDC.
Betw een Adjacent Contact Term inals: 1,000Mohms @ 500VDC.
Betw een Contacts and Coil: 1,000Mohms @ 500VDC.
Coil Data
Voltage: AC 6 - 240V.
DC 6 - 110V.
Nom inal Pow er: AC abt. 1.4VA/1.2VA (50Hz/60Hz).
DC abt. 0.9W.
Coil Tem perature Rise: AC 60°C max.
DC 50°C max.
Mechanical Data
Term ination: Plug-in, PCB.
Enclosure: Snap-on cover.
Weight: 1.26 oz (32g) approximately.
Max. Coil Pow er: 110% of nominal voltage.
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
713