Ordering information
Unit type
PAA
PAA 50
F
-5
-O
5
PAA50F
1
2
3
4
1Series name
Recommended Noise Filter
NAC-06-472
R
2Output wattage
3Universal input
4Output voltage
5Optional
C :with Coating
G :Low leakage current
J :Connector type
N :with Cover
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
R :with Remote ON/OFF
*The Noise Filter is recommended
*to connect with several devices.
MODEL
PAA50F-3
30
PAA50F-5
50
PAA50F-12
51.6
PAA50F-15
PAA50F-24
PAA50F-48
52.8
MAX OUTPUT WATTAGE[W]
DC OUTPUT
52.5
52.8
3V 10A
5V 10A
12V 4.3A
15V 3.5A
24V 2.2A
48V 1.1A
SPECIFICATIONS
MODEL
PAA50F-3
AC85 - 264 1
PAA50F-5
PAA50F-12
PAA50F-15
PAA50F-24
PAA50F-48
VOLTAGE[V]
f
ACIN 100V 0.5typ
ACIN 200V 0.25typ
0.8typ
0.4typ
CURRENT[A]
(
)
FREQUENCY[Hz]
50/60 47 - 63
INPUT
EFFICIENCY[%]
POWER FACTOR
67typ
74typ
77typ
78typ
80typ
80typ
(
)
ACIN 100V 0.95typ Io=100%
(
)
)
ACIN 100V 15typ Io=100%
INRUSH CURRENT[A]
(
ACIN 200V 15typ Io=100%
(
,
,
,
)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.75max 60Hz According to UL CSA VDE and DEN-AN
3
5
12
15
24
48
CURRENT[A]
10
10
4.3
3.5
2.2
1.1
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
80max
140max
120max
160max
50max
20max
40max
80max
140max
120max
160max
50max
60max
20max
48max
100max
120max
160max
150max
180max
120max
150max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
150max
120max
160max
150max
180max
240max
290max
96max
192max
240max
150max
200max
250max
300max
480max
600max
192max
1
1
1
1
*
*
*
*
0
to +50
C
RIPPLE[mVp-p]
-10 - 0
C
0
to +50
C
OUTPUT
RIPPLE NOISE[mVp-p]
-10 - 0
C
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50 60max
C
2
*
DRIFT[mV]
20max
(
,
)
START-UP TIME[ms]
HOLD-UP TIME[ms]
500max ACIN 85V Io=100%
(
,
)
(
,
)
(
,
)
10typ ACIN 85V Io=100% 20typ ACIN 100V Io=100% 100typ ACIN 200V Io=100%
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6
10%
t
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
PROTECTION
CIRCUIT AND
OTHERS
OVERVOLTAGE PROTECTION 4.00 - 5.25V
Works at 115 - 140% of rating
( )
LED Green
OPERATING INDICATION
REMOTE ON/OFF
(
)
Optional Refer to Instruction Manual
3
*
, , , (
AC3 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
)
INPUT-OUTPUT RC
-
, , , (
AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
)
INPUT-FG
ISOLATION
3
3
,
,
(
)
*
OUTPUT RC-FG
AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature
-
W
,
,
(
)
*
OUTPUT-RC
AC100V 1minute Cutoff current = 100mA DC100V 10M min At Room Temperature
W
,
,
,
(
) (
),
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -10 to +65
20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max
C
,
(
),
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75
20 - 90%RH Non condensing 9 000m 30 000feet max
C
ENVIRONMENT
2
,
(
),
,
,
VIBRATION
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis
196.1m/s2 20G 11ms once each X Y and Z axis
),
(
,
,
IMPACT
, , ,
UL60950-1 EN60950-1 EN50178 CSA C22.2 No.234 Complies with DEN-AN and IEC60950-1
AGENCY APPROVALS
CONDUCTED NOISE
SAFETY AND
NOISE
REGULATIONS
,
,
,
Complies with FCC-B CISPR22-B EN55022-B VCCI-B
HARMONIC ATTENUATOR Complies with IEC61000-3-2
(
) ( )
W H
X X
(
)
CASE SIZE/WEIGHT
COOLING METHOD
37 85 159mm without terminal block
D /400g max without cover
X
X
OTHERS
Convection
*1 According to 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2 Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*3 Applicable when Remote ON/OFF(optional) is added.
*
Derating is required when operated with case cover.
Distribution:
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
■
■
■
■
■
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de
A-48
Änderungen vorbehalten / subject to change without notice