Ordering information
Unit type
PAA
PAA 600
F
-5
-O
5
PAA600F
1
2
3
4
1Series name
Recommended Noise Filter
NAC-16-472
R
2Output wattage
3Universal input
4Output voltage
5Optional
C :with Coating
G :Low leakage current
R :Positive logic control
W:with Alarm signal
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The Noise Filter is recommended
*to connect with several devices.
MODEL
PAA600F-3
PAA600F-5
600
PAA600F-12
636
PAA600F-15
PAA600F-24
PAA600F-48
624
MAX OUTPUT WATTAGE[W]
DC OUTPUT
360
645
648
3V 120A
5V 120A
12V 53A
15V 43A
24V 27A
48V 13A
SPECIFICATIONS
MODEL
PAA600F-3
PAA600F-5
PAA600F-12
PAA600F-15
PAA600F-24
PAA600F-48
VOLTAGE[V]
AC85 - 264 1 or DC120 - 340
f
ACIN 100V 5.4typ
8.2typ
4.1typ
CURRENT[A]
ACIN 200V 2.7typ
(
)
FREQUENCY[Hz]
50/60 47 - 63
EFFICIENCY[%]
INPUT
70typ
76typ
80typ
81typ
83typ
83typ
(
)
)
ACIN 100V 0.99typ Io=100%
POWER FACTOR
(
ACIN 200V 0.95typ Io=100%
(
)
)
ACIN 100V 20typ Io=100%
INRUSH CURRENT[A]
(
ACIN 200V 40typ Io=100%
(
,
,
,
)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.75max 60Hz According to UL CSA VDE and DEN-AN
3
5
12
15
24
48
CURRENT[A]
120
120
53
43
27
13
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
80max
140max
120max
160max
40max
20max
40max
80max
140max
120max
160max
50max
60max
20max
48max
100max
120max
160max
150max
180max
120max
150max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
150max
120max
160max
150max
180max
240max
290max
96max
192max
300max
150max
200max
200max
300max
480max
580max
192max
1
1
1
1
*
*
*
*
0
to +50
C
RIPPLE[mVp-p]
-10 - 0
C
0
to +50
C
OUTPUT
RIPPLE NOISE[mVp-p]
-10 - 0
C
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50 50max
C
2
*
DRIFT[mV]
12max
(
,
)
START-UP TIME[ms]
HOLD-UP TIME[ms]
500max ACIN 85V Io=100%
(
,
)
20typ ACIN 100V Io=100%
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.45
10%
t
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION 4.00 - 5.25V Works at 115 - 140% of rating
PROTECTION
(
)
CIRCUIT AND OPERATING INDICATION
LED Green
OTHERS
REMOTE SENSING
Provided
Provided
REMOTE ON/OFF
, , , (
AC3 000V 1minute Cutoff current = 10mA max DC500V 50M min At Room Temperature
W
)
INPUT-OUTPUT RC
-
, , , (
AC2 000V 1minute Cutoff current = 10mA max DC500V 50M min At Room Temperature
W
)
INPUT-FG
ISOLATION
,
,
(
)
OUTPUT RC-FG
AC500V 1minute Cutoff current = 100mA max DC500V 50M min At Room Temperature
-
W
,
,
(
)
OUTPUT-RC
AC100V 1minute Cutoff current = 100mA max DC100V 50M min At Room Temperature
W
,
,
,
(
) (
),
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -10 to +65
20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max
C
,
(
),
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75
20 - 90%RH Non condensing 9 000m 30 000feet max
C
ENVIRONMENT
2
,
(
),
,
,
VIBRATION
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis
196.1m/s2 20G 11ms once each X Y and Z axis
),
(
,
,
IMPACT
, , ,
UL60950-1 EN60950-1 EN50178 CSA C22.2 No.234 Complies with DEN-AN and IEC60950-1
AGENCY APPROVALS
CONDUCTED NOISE
SAFETY AND
NOISE
REGULATIONS
,
,
,
Complies with FCC-B CISPR22-B EN55022-B VCCI-B
HARMONIC ATTENUATOR Complies with IEC61000-3-2
(
) (
)
X
CASE SIZE/WEIGHT
COOLING METHOD
190 92 200mm without terminal block and screw
W
H D /4.0kg max
X
X
X
OTHERS
(
)
Forced cooling internal fan
*1 According to 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2 Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Avoid prolonged use under over-load.
*
Distribution:
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
■
■
■
■
■
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de
A-58
Änderungen vorbehalten / subject to change without notice