P6KE SERIES
VOLTAGE 6.8V ~ 440V
600W Peak Power / 5.0W Steady State
600W Peak Power TVS
Elektronische Bauelemente
RoHS Compliant Product
Lead Free Product
FEATURES
* 600 Watts Surge Capability at 1ms
* Excellent clamping capability
* Low zener impedance
DO-15
.140(3.6)
.104(2.6)
DIA.
* Fast response time: Typically less than
1.0ps from 0 volt to BV min.
1.0(25.4)
MIN.
* Typical IR less than 1 A above 10V
* High temperature soldering guaranteed:
260 C / 10 seconds / .375"(9.5mm) lead
length, 5lbs.(2.3kg) tension
.300(7.6)
.230(5.8)
MECHANICAL DATA
* Case: Molded plastic
* Epoxy: UL 94V-0 rate flame retardant
* Lead: Axial leads, solderable per MIL-STD-202,
method 208 guaranteed
1.0(25.4)
MIN.
.034(.9)
.028(.7)
DIA.
* Polarity: Color band denotes cathode end
* Mounting position: Any
Dimensions in inches and (millimeters)
*
Weight: 0.40 grams
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature unless otherwise specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
RATINGS
SYMBOL
VALUE
UNITS
Peak Power Dissipation at TA=25 C, TP=1ms(NOTE 1)
Steady State Power Dissipation at TL=75 C
Lead Length .375"(9.5mm) (NOTE 2)
PPK
Minimum 600
Watts
PD
5.0
Watts
Peak Forward Surge Current at 8.3ms Single Half Sine-Wave
IFSM
100
Amps
C
superimposed on rated load (JEDEC method) (NOTE 3)
Operating and Storage Temperature Range
TJ, TSTG
-55 to +175
NOTES:
1. Non-repetitive current pulse per Fig. 3 and derated above TA=25 C per Fig. 2.
2. Mounted on Copper Pad area of 1.6" X 1.6" (40mm X 40mm) per Fig.5.
3. 8.3ms single half sine-wave, duty cycle = 4 pulses per minute maximum.
DEVICES FOR BIPOLAR APPLICATIONS
1. For Bidirectional use C or CA Suffix for types P6KE6.8 thru P6KE440.
2. Electrical characteristics apply in both directions.
http://www.SeCoSGmbH.com
Any changing of specification will not be informed individual
01-Jun-2002 Rev. A
Page 1 of 4