描述
KLEMMENGEHAEUSE 8 SAK 4

OE-1002 数据手册

 浏览型号OE-1002的Datasheet PDF文件第2页 
Terminal boxes, to European Standards (ATEX)  
Terminal box  
Features  
þ ATEX certification  
Terminal box  
Terminal box, empty enclosure  
Type OTB-122  
Type OEB-122  
þ BASEEFA test certification  
lbcak  
þ Versions with horizontally, vertically  
or diagonally mounted terminal strip  
Explosion protection  
þ Different terminal types can be mounted  
þ External earth connection  
Ex protection type (according to EN 50014)  
Ex II 2 GD T 85°C, EEx e II T6 increased safety  
BS EN 50014, BS EN 50019; 1994  
BS EN 50281-1-1; 1998  
þ Extended ambient temperature range  
þ Possibility of an M 20/M 25 cable entry  
Ambient temperature  
(special temperature range on request)  
- 20 °C to + 40 °C  
extended ambient temperature range  
- 55 °C to + 65 °C  
in the lid  
þ Integrated earthing pad for metal glands  
Technical data  
Description  
Material  
polyester black, anti-static,  
glass-fibre reinforced,  
The OTB terminal box, both distribution box and  
empty enclosure, is manufactured of high impact  
resistance proof, glass-fibre reinforced polyester  
SMC & DMC providing extraordinary stability and  
corrosion resistance.  
surface resistance <109  
flame retardant: IEC 92.1, UL94V0  
Colour/coating  
polyester black, anti-static  
Lid screws  
(other models on request)  
captive slotted or hexagon socket screw,  
high-quality stainless steel 316  
The standard enclosure consists of black, anti-  
static material. OTB distribution box and empty  
enclosure have been tested and approved by the  
BASEEFA authorities according to the latest  
European Standards. These correspond to the  
requirements of the EC directive 94/9/EC (ATEX).  
Standard-seals  
(seals on request)  
captive silicone o-ring in groove,  
protected against the penetration  
of foreign bodies, according to IP 66  
(IEC 144/EN 60529) - 55 °C to + 80 °C  
Mechanical resistance  
impact energy > 2 x 7 Nm  
(according to EN 50014)  
Installation instructions  
Protection class EN 60529/IEC 60529  
The installer must make sure that the enclosure  
used is suitable for the corresponding field of  
application. This means that the marking must  
correspond to the classification of the Ex area.  
Also must the temperature class of the distribution  
box meet the respective requirements.  
(higher protection class on request)  
IP 66  
Max. power dissipation  
at Tu + 40 °C, 4 W  
at Tu + 55 °C, 2 W  
at Tu + 65 °C, 1.3 W  
Certification  
(further certifications on request)  
empty enclosure: part certification  
BAS98ATEX3007U  
distribution box: conformity certification  
BAS98ATEX3008X  
Accessories  
Earthing bars OS3, XE earthing studs,  
ES earthing studs  
2/18  

与OE-1002相关器件

型号 品牌 获取价格 描述 数据表
OE-1004 ETC

获取价格

KLEMMENGEHAEUSE 6 SAK 6N
OE-1008 ETC

获取价格

KLEMMENGEHAEUSE 1 MK6/6
OE-1012 ETC

获取价格

KLEMMENGEHAEUSE 1BA4
OE-1130 ETC

获取价格

TERMINAL BOX EX
OE-1131 ETC

获取价格

TERMINAL BOX EX RED
OE1900AO CHERRY

获取价格

GENERAL PURPOSE – DOUBLE POLE
OE1900HO CHERRY

获取价格

GENERAL PURPOSE – DOUBLE POLE
OE1900JO CHERRY

获取价格

GENERAL PURPOSE – DOUBLE POLE
OE1900KO CHERRY

获取价格

GENERAL PURPOSE – DOUBLE POLE
OE1900MO CHERRY

获取价格

GENERAL PURPOSE – DOUBLE POLE