5秒后页面跳转
NIPXI-2584 PDF预览

NIPXI-2584

更新时间: 2024-11-09 05:54:03
品牌 Logo 应用领域
美国国家仪器公司 - NI 转换器
页数 文件大小 规格书
4页 549K
描述
Dual 6x1 1-wire, 12x1 1-wire,6x1 2-wire, interleaved 11x1 2-wire multiplexer configuration

NIPXI-2584 数据手册

 浏览型号NIPXI-2584的Datasheet PDF文件第2页浏览型号NIPXI-2584的Datasheet PDF文件第3页浏览型号NIPXI-2584的Datasheet PDF文件第4页 
12-Channel, 300 V CAT II, 600 V CAT I Multiplexer  
NI PXI-2584 NEW!  
• Dual 6x1 1-wire, 12x1 1-wire,  
6x1 2-wire, interleaved 11x1 2-wire  
multiplexer configuration  
Operating Systems  
• Windows 2000/XP  
• Linux®  
• Switching capacity  
Recommended Software  
• NI Switch Executive  
• LabVIEW  
• LabWindows/CVI  
• Measurement Studio  
• Up to 300 V CAT II, 600 V CAT I  
• Up to 0.5 A switching/0.5 A carry  
• Up to 10 W  
• 600 channels/s  
• Onboard relay counting  
• Fully software programmable  
Other Compatible Software  
• Visual Basic  
• C/C++  
• 32,000-step scanlist for  
deterministic scanning  
• Tight synchronization with instruments  
through hardware triggers  
Driver Software (included)  
• NI-SWITCH  
• NI-DAQmx  
Overview  
The National Instruments PXI-2584 is a high-voltage multiplexer  
switch in a single-slot, 3U PXI module. With a CAT II certification at  
300 V, it is capable of routing general-purpose ATE loads or high-voltage,  
low-current signals. The 600 V CAT I channel-to-ground isolation on the  
NI PXI-2584 makes it ideal for fuel cell and battery stack applications.  
You also can use the module in multimodule configurations for taking  
measurements on hundreds of channels. The CAT I and CAT II safety  
ratings combined with UL safety certification make it ideally suited for  
high-voltage ATE systems that include the NI PXI-4071 1000 V digital  
multimeter. The reed relays in the PXI-2584 also ensure longer  
lifetimes and faster actuation times for test equipment.  
Interleaved Topology for  
Maximum Channel Count  
Interleaved topology is a method to increase channel count when  
measuring potentials that are on a stack such as battery stacks and fuel  
cell stacks. In traditional 2-wire topologies, each channel would put two  
wires across each component under test, which would limit the PXI-2584  
to six differential channels. By putting each single input pin on the front  
connector at points in between potentials on a stack, the channel count  
is extended from six to 11 2-wire channels. In addition to maximizing  
channel count on a module, the topology offers a free “straddle”  
channel when testing battery stacks over multiple modules.  
The PXI-2584 Interleaved Topology Maximizes Channel Count  

与NIPXI-2584相关器件

型号 品牌 获取价格 描述 数据表
NIPXI-2585 NI

获取价格

10-Channel, 12 A SPST (Form A) Relays/Multiplexer
NIPXI-2586 NI

获取价格

10-Channel, 12 A SPST (Form A) Relays/Multiplexer
NIPXI-2590 NI

获取价格

4x1 unterminated multiplexer/50 characteristic impedance
NIPXI-2591 NI

获取价格

4x1 unterminated multiplexer/50 characteristic impedance
NIPXI-2593 NI

获取价格

250 MS/s, 125 MHz, 8-Bit Digitizers
NIPXI-2595 NI

获取价格

5 GHz 4x1 and Quad 4x1 Multiplexers
NIPXI-2596 NI

获取价格

26.5 GHz Multiplexers, SPDT Relays, and Transfer Switches
NIPXI-2597 NI

获取价格

26.5 GHz Multiplexers, SPDT Relays, and Transfer Switches
NIPXI-2598 NI

获取价格

26.5 GHz Multiplexers, SPDT Relays, and Transfer Switches
NIPXI-2599 NI

获取价格

26.5 GHz Multiplexers, SPDT Relays, and Transfer Switches