Full-Featured E Series Multifunction DAQ
12 or 16-Bit, up to 1.25 MS/s, up to 64 Analog Inputs
E Series – Full-Featured
• 16 or 64 analog inputs at up to
1.25 MS/s, 12 or 16-bit resolution
• 2 analog outputs at up to 1 MS/s,
12 or 16-bit resolution
• 8 digital I/O lines (TTL/CMOS);
two 24-bit counter/timers
Operating Systems
• Windows 2000/NT/XP
• Real-time performance with
LabVIEW (page 134)
• Others such as Linux and Mac OS X
(page 187)
• Analog and digital triggering
• 14 or 15 analog input signal ranges
• NI-DAQ driver simplifies
Recommended Software
• LabVIEW
• LabWindows/CVI
• Measurement Studio
• VI Logger
configuration and measurements
Families
Other Compatible Software
• NI 6071E
• Visual Basic, C/C++, and C#
• NI 6070E
• NI 6062E
Driver Software (included)
• NI 6052E
• NI-DAQ 7
• NI 6040E
• NI 6033E
Calibration Certificate Included
• NI 6032E
See page 21.
• NI 6031E
• NI 6030E
• NI 6020E (only digital triggering)
Analog
Inputs
Input
Max
Input
Range
Analog
Outputs Resolution
Output
Output
Rate
Output
Range
Family
Bus
Resolution Sampling Rate
Digital I/O Counter/Timers
Triggers
NI 6071E
NI 6070E
NI 6062E
NI 6052E
NI 6040E
NI 6033E
NI 6032E
NI 6031E
NI 6030E
NI 6020E
PCI, PXI
PCI, PXI, FireWire
PCMCIA
PCI, PXI, FireWire
PCI, PXI
64 SE/32 DI
16 SE/8 DI
16 SE/8 DI
16 SE/8 DI
16 SE/8 DI
64 SE/32 DI
16 SE/8 DI
64 SE/32 DI
16 SE/8 DI
16 SE/8 DI
12 bits
12 bits
12 bits
16 bits
12 bits
16 bits
16 bits
16 bits
16 bits
12 bits
1.25 MS/s
1.25 MS/s
500 kS/s
333 kS/s
500 kS/s
100 kS/s
100 kS/s
100 kS/s
100 kS/s
100 kS/s
0.05 tꢀ 10 ꢁ
0.05 tꢀ 10 ꢁ
0.05 tꢀ 10 ꢁ
0.05 tꢀ 10 ꢁ
0.05 tꢀ 10 ꢁ
0.1 tꢀ 10 ꢁ
0.1 tꢀ 10 ꢁ
0.1 tꢀ 10 ꢁ
0.1 tꢀ 10 ꢁ
0.05 tꢀ 10 ꢁ
2
2
2
2
2
0
0
2
2
2
12 bits
12 bits
12 bits
16 bits
12 bits
-
1 MS/s
1 MS/s
850 kS/s
333 kS/s
1 MS/s
-
10 ꢁ
10 ꢁ
10 ꢁ
10 ꢁ
10 ꢁ
-
8
8
8
8
8
8
8
8
8
8
2, 24-bit
2, 24-bit
2, 24-bit
2, 24-bit
2, 24-bit
2, 24-bit
2, 24-bit
2, 24-bit
2, 24-bit
2, 24-bit
Analꢀg, digital
Analꢀg, digital
Analꢀg, digital
Analꢀg, digital
Analꢀg, digital
Analꢀg, digital
Analꢀg, digital
Analꢀg, digital
Analꢀg, digital
Digital
PCI
PCI
PCI, PXI
PCI, PXI
-
-
-
16 bits
16 bits
12 bits
100 kS/s
100 kS/s
20 S/s
10 ꢁ
10 ꢁ
10 ꢁ
NI USB
Table 1. NI Full-Featured E Series Model Guide (See page 228 for detailed specifications.)
Overview and Applications
Highly Accurate Hardware Design
NI Full-Featured E Series devices are the fastest and the most accurate NI Full-Featured E Series DAQ devices includethe following features
multiplexed data acquisition devices available. They are ideal for and technologies:
applications ranging from continuous high-speed data logging to
control applications to high voltage signal or sensor measurements Temperature Drift Protection Circuitry – Designed with components
when used with NI signal conditioning. Synchronize the operations that minimize the effect of temperature changes on measurements to
of multiple devices using the RTSI bus or PXI trigger bus and easily less than 0.0006% of reading per °C.
integrate other hardware such as motion control and machine vision
to create an entire measurement and control system.
Resolution-Improvement Technologies – Carefully designed noise
floor maximizes resolution.
Visit ni.com/oem for information on our
quantity discounts for OEM customers.
Onboard Self-Calibration – Precise voltage reference included
for calibration and measurement accuracy. Self-calibration is
completely software controlled, with no potentiometers to adjust.
NI DAQ-STC – Timing and control ASIC designed to provide more
flexibility, lower power consumption, and a higher immunity to noise
and jitter than off-the-shelf counter/timer chips.
National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com 199