NFS42 SERIES
Triple output
• 6.3 x 3.9 x 1.5 package (1U applications )
• Ove rvoltage and s hort circuit prote ction
• 40W with fre e air conve ction
• EN55022, EN55011 conducte d e mis s ions le ve l B
• UL, VDE, CSA and BABT s afe ty approvals
The NFS42 series is a 40W universal input AC/DC power supply on a 6.3 x 3.9
inch card with a maximum component height of 1.5 inches for use in 1U
applications. The NFS42 series is available in three standard models with a
lower component count and larger footprint than most standard 40W models to
ensure greater reliability. The NFS42 provides 40W of output power with free air
convection cooling which can be boosted to 50W with 20CFM of air. Standard
features include overvoltage and short circuit protection. The series, with full
international safety approval and the CE mark, meets conducted emissions
EN55022 level B. The NFS42 series is designed for use in low power telecom
and industrial applications such as PABX's, industrial PC's and machine control.
[ 2 YEAR WARRANTY ]
SPECIFICATION All specifications are typical for 110VAC input, 40 watts output at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Line regulation
LL to HL, FL
Main output (Output 1)
Output 2
Output 3
±1.0%
±1.0%
±0.1%
Conducted emissions
Radiated emissions
ESD air
EN55022, FCC part 15
Level B
Level B
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Perf. criteria 2
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 2
Perf. criteria 1
ESD contact
Surge
Total regulation
(See Note 5)
Main output (Output 1)
Output 2
Output 3
±3.0%
±5.0%
±5.0%
Fast transients
Radiated immunity
Conducted immunity
Overshoot/undershoot At turn-on
0%
GENERAL SPECIFICATIONS
Transient response
+5V (1.5A to 3A)
500mV max. dev.,
500µs recovery
Hold-up time
110VAC input
230VAC input
16ms
100ms
Temperature coefficient All Outputs
Overvoltage protection +5V output
±0.03% /°C, max.
6.25V ±0.75V
Efficiency
110/230VAC input,
40W output
70% typical
65% min.
Isolation voltage
Switching frequency
Input/output
Input/chassis
3000VAC
1500VAC
Output power limit
Primary power 75W input power limit
limited
50W output power limit
Yes, with auto-restart
4 Watts
Variable
20kHz, min.
Short circuit protection
Approvals and
standards
(See Note 10)
VDE0805, EN60950, IEC950
IEC1010, UL1950, BABT
CSA C22.2 No. 950
Minimum output current (See Note 8)
INPUT SPECIFICATIONS
Weight
400g (14oz)
Input voltage range
Universal input
85 to 264VAC
120 to 370VDC
MTBF (See Note 8)
MIL-HDBK-217E, 25°C 230,000 hours
ENVIRONMENTAL SPECIFICATIONS
Input frequency range
47 to 440Hz
Thermal performance
(See Notes 6, 7)
0°C to 50°C ambient,
40W
50W
Maximum input
surge current
110VAC, cold start
230VAC, cold start
7.5A
15A
convection cooled
0°C to 50°C ambient,
20CFM forced air
50°C to 70°C ambient Derate linearly
to 50% load
Safety ground
leakage current
110VAC, 60Hz
230VAC, 50Hz
0.66mA max.
1.2mA max.
International Safety Standard Approvals
Peak (0°C to 50°C, max. 30s)
50W
VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1036
Licence No. 1485, 1650
Operating range,
see derating curve
0°C to +70°C
Non-operating
-40°C to +85°C
5% to 95% RH
UL1950 File No. E136005
Relative humidity
Altitude
Non-condensing
CSA C22.2 No. 950 File No. LR41062C
Certificate No. PS/603173
Operating
Non-operating
10,000 feet max.
30,000 feet max.
Vibration (See Note 9) 5Hz to 500Hz
2.4G rms approx.
PAGE 1