Ordering information
Ultra high-attenuation type of common mode noise from 10kHz to 1MHz
NAH -10 -472 -O
NAH series
1
2
3
4
1Model Name
2Rated Current
3Line to ground capacitor code:See table 1.1.
R
table1.1 Line to ground capacitor code
Line to ground
Leakage Current
Code
capacitor
(nominal value)
Not Provided
100pF
(Input 125/250V 60Hz)
A/ 10 A max
12.5 A/ 25 A max
25 A/ 50 A max
37.5 A/ 75 A max
50 A/100 A max
000
101
221
331
471
681
102
222
332
472
5
220pF
330pF
470pF
75.5 A/150 A max
0.13mA/0.25mA max
0.25mA/0.5 mA max
0.38mA/0.75mA max
0.5 mA/1.0 mA max
680pF
1000pF
2200pF
3300pF
4700pF
The terminal cover is retracted inside the unit
DIN rail installation type is option
When the line to ground capacitor code is
different, the attenuation characteristic is
different.
*
4Options
D:DIN rail installation type
The dimensions change when the option is set.
Refer to External view.
*
Features of NAH series
Ultra high-attenuation type of common mode noise from 10kHz to 1MHz
-Single Phase 250 VAC
-Push down type terminal block
Specifications
No.
Items
NAH-06-472
NAH-10-472
NAH-16-472
NAH-20-472
NAH-30-472
1
Rated Voltage[V]
AC 1f250 / DC250
2
Rated Current[A]
6
10
16
20
30
3
Test Voltage (Terminal-Mounting Plate)
2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity
4
Isolation Resistance (Terminal-Mounting Plate) 500 VDC 100MWmin at room temperature and humidity
5
Leakage current 125/250V 60Hz
Voltage drop
0.5mA/1.0mA max
6
1.0V max
7
Safety agency approval temperatures
Operating temperature
Operating humidity
-25 to +85C(Refer to Derating Curve)
-40 to +85C(Refer to Derating Curve)
20 to 95%RH (Non condensing)
-40 to +85C/20 to 95%RH (Non condensing)
8
9
10
11
12
13
14
Storage temperature/humidity
Vibration
2
10 to 55Hz, 19.6m/s (2G), 3min. Period, 1hour each X, Y and Z axis
2
Impact
196.1m/s (20G), 11ms Once each X, Y and Z axis
Safety agency approvals
Case size (without projection) /Weight
UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input)
53X41X92 mm [2.09X1.61X3.62 inches] (WXHXD) /300g max (Option : -D refer to external view)
Circuit Diagram
Derating Curve
Case
100
80
3
1
60
CY
CY
LOAD
LINE
40
20
2
4
0
-40
-30
-20
40
50 55 60
70
80
90
Ambient Temperature [C]
: Mounting Plate
CY : Line to ground capacitor
NA-3