NETWORK ELEMENT TIMING GENERATOR
C O N N O R THE CONNOR-WINFIELD CORPꢀ
2111 COMPREHENSIVE DRIVEꢀ
AURORA, IL 60505ꢀ
FAX (630) 851-5040ꢀ
PHONE (630) 851-4722
HTTP://WWWꢀCONWINꢀCOM
W I N F I E L D
STRATUM 3 SIMPLIFIED CONTROL
TIMING MODULES (MSTM-S3-INT)
DESCRIPTION
MSTM-S3 PIN ASSIGNMENT
The Connor-Winfield Stratum 3 Simplified Control
Timing Module acts as a complete system clock module for general
Stratum 3 timing applicationsꢀ The MSTM is designed for
external control functionsꢀ Full external control input allows for
selection and monitoring of any of four possible operating states:
1) Holdover, 2) External Reference #1, 3) External Reference
#2, and 4) Free Runꢀ The table below illustrates the control signal
inputs and corresponding operational states:
HOLDOVER
REF 1
+5Vdc
EX REF 1
REF 2
FRERUN
GND
GND
EX REF 2
GND
ALARM OUT
CNTL A
CLK_OUT
GND
CNTL B
SYNC_OUT
GND
PLL TVL
In the absence of External Control Inputs (A,B), the
MSTM enters the Free Run mode and signals an External Alarmꢀ
The MSTM will enter other operating modes upon application of
a proper control signalꢀ Mode 1 operation (A=1, B=0) results in
an output signal that is phase locked to the External Reference
Input #1ꢀ Mode 2 operation (A=0, B=1) results in an output signal
that is phase locked to External Reference Input #2ꢀ Holdover
mode operation (A=1, B=1) results in an output signal at or near
the frequency as determined by the latest (last) locked-signal input
values and the holdover performance of the MSTMꢀ
BOTTOM VIEW
BLOCK DIAGRAM
0
1
2
FRERUN
CNTL
CNTL
A
B
REF
REF
1
2
PLL TVL
Alarm signals are generated at the Alarm Output during
Holdover and Free Run operationꢀ Alarm Signals are also
generated by loss-of-lock, loss of Reference, and by a Tune-Limit
indication from the PLLꢀ A Tune-Limit alarm signal indicates
that the VCXO tuning voltage is approaching within 10% the limits
of its lock capability and that the External Reference Input may
be erroneousꢀ A high level indicates an alarm conditionꢀ Real-
time indication of the operational mode is available at unique
operating mode outputs on pins 1-4ꢀ
FREE RUN
2:4
3
HOLDOVER
HOLDOVER
ALARM
OUT
LOCK AND
PHASE
DETECTION
EX REF
EX REF
1
2
2:1
MUX
COMPARATOR
2:1
MUX
SYNC_OUT
DAC
DAC
FIFO
STRATUM3
VCXO
FILTERS
TUNING
VOLTAGE
MONITOR
STRATUM3
TCXO
CLK_OUT
PLL TVL
Control loop filters effectively attenuate any reference
jitter and smooth out phase transientsꢀ
MSTM-S3
CONTROL
INPUT
ALARM
OUTPUT
OPERATIONAL MODE
REF 1
REF 2
HLDOVER
FRERUN
PLL_TVL*
A
B
0
0
Free Run (Default)
0
0
0
1
0
1
External
Reference
#1
Normal
Tune Limit
LOS + LOL
1
1
1
0
0
0
0
0
0
0
0
0
0
1
0
0
1
1
1
0
External
Reference
#2
Normal
Tune Limit
LOS + LOL
0
0
0
1
1
1
0
0
0
0
0
0
0
1
0
0
1
1
0
1
1
1
Holdover
0
0
1
0
0
1
INT
DATA SHEET #: _T_M__0_1_1______ PAGE___1___ OF ___6____ REV:__0_0_____ DATE:___1_0_/_4_9_9____ © Copyright 1999 Connor-Winfield all rights reservedꢀ