85/85 THB – Safety Agency Approved
FEATURES
Metalized Polypropylene
MPX for X2, Across the Line
MPXB for In Series with Mains
EMI Filters – Outdoor Applications
APPLICATIONS
Operating Temperature Range
Capacitance Tolerance
-40°C to +110°C
+10% or +20% at 1 kHz, 25°C
UL/CSA
ENEC
CQC
AC voltage
(50/60 Hz)
275/305
275/305
305
Tan δ
Dissipation Factor
at 1 kHz and 25°C
0.01uF≤Cn≤1.0 uF
1.0uF<Cn≤10.0 uF
Cn>10.0 uF
≤0.1%
≤0.3%
≤0.4%
Capacitance
<0.33uF
Terminal to Terminal
Terminal to Case
Insulation Resistance
@25°C (<70% RH) for 1 minute
at 100VDC applied
>30000 MΩ at 100VDC
>5000 MΩ at 500VDC
>30000 MΩ at 100VDC
>5000 MΩ at 500VDC
15,000 MΩ
>0.33uF
5,000 MΩxuF
Self-Inductance
<1 nano-Henry per mm of lead spacing and lead length
1312 VDC applied for 60 seconds or
2000 VDC applied for 2 seconds
Cut-off current: 2A ac or 10mAdc
Current limiting resistance: 1Ω/V
Terminal to Terminal
Terminal to case
Dielectric Strength
2050VDC (50/60 Hz) applied between the terminals and case for 60
Seconds and 25°C
100,000 hours at Un @Hot-Spot temperature T=85°C
Capacitance change
Dissipation Factor
<10% of initially measured value
<1.0% at 1kHz
>100% of initially specified value (T-T)
>3000 MΩ (Terminal to case)
Life Expectancy
Humidity test
Insulation Resistance
Temperature: 85°C + 2°C; Humidity: 85% + 2%
Loading Voltage: 240Vac (50Hz/60Hz)
Duration: 1000 hours
Capacitance change
Dissipation Factor
<10% of initially measured value
<1.0% at 1kHz
>50% of initially specified value (T-T)
>15000 MΩ (Terminal to case)
C< 1uF Vp=2.5kVDC
Insulation Resistance
Impulse voltage
(24 pulses)
C> 1uF Vp=2.5kV √C
Capacitance temperature
coefficient
-200ppm/°C, +100ppm/°C
Construction
Electrodes
Metallized Polypropylene film
Vacuum deposited Metal layers
Coating
Flame retardant Solvent resistant plastic case with epoxy end fill (UL94V-0)
Lead Free Tinned Leads
Lead terminations
Special Order Options
May23