5秒后页面跳转
MPU200-4530MG PDF预览

MPU200-4530MG

更新时间: 2024-11-16 04:50:27
品牌 Logo 应用领域
BEL /
页数 文件大小 规格书
6页 214K
描述
DC-DC Regulated Power Supply Module, 4 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-10

MPU200-4530MG 数据手册

 浏览型号MPU200-4530MG的Datasheet PDF文件第2页浏览型号MPU200-4530MG的Datasheet PDF文件第3页浏览型号MPU200-4530MG的Datasheet PDF文件第4页浏览型号MPU200-4530MG的Datasheet PDF文件第5页浏览型号MPU200-4530MG的Datasheet PDF文件第6页 
MPU200/MDU200 Series Data Sheet  
Features  
RoHS lead free solder and lead solder exempted products  
are available  
Power Factor Correction (PFC) meets EN61000-3-2  
Same size, airflow, and construction as MPU150/MDU150  
with over 33% more power  
Single-wire current sense on quad model outputs V1 and V2  
Remote sense on quad model outputs V1 and V2  
Current share and N+1 redundancy (standard on all models)  
Overtemperature, overload, and overvoltage protection  
Available with SAE mountings  
MDU200 models have 48 VDC input  
Description  
The MPU200/MDU200 Series is based upon the proven architecture of the MPU150/MDU150 product line. The MPU products  
incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints. In this series,  
200 watts of continuous output power is provided with single or multiple output units suited for distributed power or central power  
applications. The series provides high current +3.3V and +5V on a single platform to support mixed-mode, high-speed digital  
circuitry.  
Power-One's dual-converter architecture combines high reliability with exceptional regulation. All multiple-output models feature  
remote sense on outputs V1 and V2 to provide independent compensation of output cable losses.  
Other standard features include independent current sharing on V1 and V2 quad-model outputs, thermal shutdown, and remote  
inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of greater than 4.0 watts per cubic inch.  
The MDU200 Series provides the same benefits as the MPU200 Series, with a nominal 48 VDC input.  
AC Input, Single-Output Model Selection  
200W/225W PK WITH 300 LFM FORCED-AIR COOLING (NOTE 1)  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
MAXIMUM OUTPUT  
CURRENT (NOTE 2)  
PEAK OUTPUT  
CURRENT (NOTE 2) REGULATION  
LINE  
LOAD  
REGULATION  
RIPPLE & NOISE  
%p-p (NOTE 3)  
INITIAL SETTING  
ACCURACY  
MODEL  
MPU200-1012G  
MPU200-1024G  
MPU200-1048G  
12V  
24V  
48V  
11.6V to 16V  
22.8V to 29.2V  
45V to 56V  
17.0A  
8.35A  
4.2A  
19.0A  
9.4A  
4.7A  
0.1%  
0.1%  
0.1%  
1%  
1%  
1%  
1%  
1%  
1%  
11.97V to 12.03V  
23.95V to 24.05V  
47.9V to 48.1V  
AC Input, Multiple-Output Model Selection  
200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1)  
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
MAXIMUM OUTPUT  
CURRENT (NOTE 2)  
LINE  
REGULATION  
LOAD  
REGULATION  
RIPPLE & NOISE  
%Pk-Pk (NOTE 3)  
INITIAL SETTING  
ACCURACY  
MODEL  
+5V  
+3.3V  
12V  
5.0V to 5.5V  
3.15V to 3.60V  
10.8V to 13.2V  
10.8V to 13.2V  
30A (Note 4)  
15A (Note 4)  
8A (Note 5)  
4A (Note 5)  
0.4%  
0.6%  
0.4%  
0.4%  
1%  
1.5%  
10%  
10%  
1%  
1.5%  
1%  
4.98V to 5.02V  
3.28V to 3.32V  
11.94V to 12.06V  
11.60V to 12.40V  
MPU200-4530  
12V  
1%  
NOTES: 1) This product is not rated for convection applications.  
2) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions. It is recommended that the airflow be  
applied from the input side of the power supply blowing towards the output.  
3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.  
4) Total current for V1 and V2 is not to exceed 35A.  
5) Total power on V3 and V4 is not to exceed 100W.  
Model numbers highlighted in yellow or shaded are not recommended for new designs.  
Ordering Information:  
OPTIONS  
SUFFIXES TO ADD TO PART NUMBER  
Metric Mounting  
Add “M” as a suffix to the model number to order chassis with  
M3 x 0.7 mounting inserts. Consult factory for availability.  
Isolation Diode  
Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed.  
Consult factory for availability.  
RoHS lead solder exemption  
No RoHS suffix character required.  
RoHS compliant for all 6 substances  
Add “G” as the last character of the part number.  
MCD10010 Rev. 1.1, 27-Jan-10  
Page 1 of 6  
www.power-one.com  

与MPU200-4530MG相关器件

型号 品牌 获取价格 描述 数据表
MPU-240S MPD

获取价格

Compact U-Channel, 240W Power Factor Corrected, AC/DC Power Supplies
MPU-240S-05YZ MPD

获取价格

Compact U-Channel, 240W Power Factor Corrected, AC/DC Power Supplies
MPU-240S-12YZ MPD

获取价格

Compact U-Channel, 240W Power Factor Corrected, AC/DC Power Supplies
MPU-240S-15YZ MPD

获取价格

Compact U-Channel, 240W Power Factor Corrected, AC/DC Power Supplies
MPU-240S-24YZ MPD

获取价格

Compact U-Channel, 240W Power Factor Corrected, AC/DC Power Supplies
MPU-240S-28YZ MPD

获取价格

Compact U-Channel, 240W Power Factor Corrected, AC/DC Power Supplies
MPU-240S-32YZ MPD

获取价格

Compact U-Channel, 240W Power Factor Corrected, AC/DC Power Supplies
MPU-240S-38YZ MPD

获取价格

Compact U-Channel, 240W Power Factor Corrected, AC/DC Power Supplies
MPU-240S-48YZ MPD

获取价格

Compact U-Channel, 240W Power Factor Corrected, AC/DC Power Supplies
MPU-250 MPD

获取价格

Single Output 250W Power Factor Corrected AC/DC Power Supplies