MPU200/MDU200 Series Data Sheet
Features
•
RoHS lead free solder and lead solder exempted products
are available
•
•
Power Factor Correction (PFC) meets EN61000-3-2
Same size, airflow, and construction as MPU150/MDU150
with over 33% more power
•
•
•
•
•
•
Single-wire current sense on quad model outputs V1 and V2
Remote sense on quad model outputs V1 and V2
Current share and N+1 redundancy (standard on all models)
Overtemperature, overload, and overvoltage protection
Available with SAE mountings
MDU200 models have 48 VDC input
Description
The MPU200/MDU200 Series is based upon the proven architecture of the MPU150/MDU150 product line. The MPU products
incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints. In this series,
200 watts of continuous output power is provided with single or multiple output units suited for distributed power or central power
applications. The series provides high current +3.3V and +5V on a single platform to support mixed-mode, high-speed digital
circuitry.
Power-One's dual-converter architecture combines high reliability with exceptional regulation. All multiple-output models feature
remote sense on outputs V1 and V2 to provide independent compensation of output cable losses.
Other standard features include independent current sharing on V1 and V2 quad-model outputs, thermal shutdown, and remote
inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of greater than 4.0 watts per cubic inch.
The MDU200 Series provides the same benefits as the MPU200 Series, with a nominal 48 VDC input.
AC Input, Single-Output Model Selection
200W/225W PK WITH 300 LFM FORCED-AIR COOLING (NOTE 1)
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT (NOTE 2)
PEAK OUTPUT
CURRENT (NOTE 2) REGULATION
LINE
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 3)
INITIAL SETTING
ACCURACY
MODEL
MPU200-1012G
MPU200-1024G
MPU200-1048G
12V
24V
48V
11.6V to 16V
22.8V to 29.2V
45V to 56V
17.0A
8.35A
4.2A
19.0A
9.4A
4.7A
0.1%
0.1%
0.1%
1%
1%
1%
1%
1%
1%
11.97V to 12.03V
23.95V to 24.05V
47.9V to 48.1V
AC Input, Multiple-Output Model Selection
200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1)
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT (NOTE 2)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%Pk-Pk (NOTE 3)
INITIAL SETTING
ACCURACY
MODEL
+5V
+3.3V
12V
5.0V to 5.5V
3.15V to 3.60V
10.8V to 13.2V
10.8V to 13.2V
30A (Note 4)
15A (Note 4)
8A (Note 5)
4A (Note 5)
0.4%
0.6%
0.4%
0.4%
1%
1.5%
10%
10%
1%
1.5%
1%
4.98V to 5.02V
3.28V to 3.32V
11.94V to 12.06V
11.60V to 12.40V
MPU200-4530
12V
1%
NOTES: 1) This product is not rated for convection applications.
2) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions. It is recommended that the airflow be
applied from the input side of the power supply blowing towards the output.
3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
4) Total current for V1 and V2 is not to exceed 35A.
5) Total power on V3 and V4 is not to exceed 100W.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
Ordering Information:
OPTIONS
SUFFIXES TO ADD TO PART NUMBER
Metric Mounting
Add “M” as a suffix to the model number to order chassis with
M3 x 0.7 mounting inserts. Consult factory for availability.
Isolation Diode
Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed.
Consult factory for availability.
RoHS lead solder exemption
No RoHS suffix character required.
RoHS compliant for all 6 substances
Add “G” as the last character of the part number.