Series
MPU-240S
CompactU-Channel,240W
Power Factor Corrected,
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 240W Output Power
• Universal 90-264 AC Input
• Low Profile U-Channel
• Power Factor Correction
• EN 60950 Approved
Parameter
Conditions
Min.
90
120
47
Typ.
Max.
264
370
63
Units
VAC
VDC
Hz
Universal
Input Voltage Range
Input Frequency
Input Current
See Model Selection Guide
Cold Start, 115 VAC
Cold Start, 230 VAC
115 VAC 0.98
30.0
60.0
Inrush Current
A Pk
• 7 Single Output Models
• Meets EN 55022 B
Power Factor Correction, See Note 1
W/VA
mA
230 VAC 0.95
Safety Ground Leakage Current
Output
Parameter
0.50
• “Finger Safe” Cover Avail.
• DIN Rail Kit Available
Conditions
Min.
Typ.
Max.
Units
Output Voltage/Current
Output Voltage Accuracy
Line Regulation
See Model Selection Guide
2.0
%
%
%
VIN = Min to Max
1.0
1.0
Load Regulation
IOUT = 5% to 100%
Ripple & Noise (20 MHz), See Note 2
See Model Selection Guide
U-Channel
With Cover
13
20
Hold-Up Time< 115 VAC
mSec
Temperature Coefficient
Overload Protection
0.03
%/°C
%IOUT
See Note 3 130
180
Over Voltage Protection, See Note 4
Short Circuit Protection, See Note 4
General
Latch Off (See Model Selection Guide)
Latch Off
Parameter
Conditions
Input to Output
Min.
4,000
5,656
Typ.
Max.
Units
VAC
VDC
Isolation Voltage
Input to Ground 2,000
Output to Ground 500
VAC
kHz
Switching Frequency
EMI Characteristics
Parameter
65
Standard
Criteria
Level
Radiated Emissions
Conducted Emissions
Noise Immunity (EMS)
EN 55022
EN 55022
EN 55024
B
B
1 kV (L-N)
2 kV (L-FG & N-FG)
Surge
EN 61000-4-4
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Conditions
Min.
-10
-25
Typ.
+25
Max.
+70
+85
Units
°C
°C
Ambient
Free Air Convection (See Derating Curve)
RH, Non-condensing 95
Humidity
%
Physical
Size
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
See Mechanical Drawings (Pages 3 & 4)
U-Channel
With Cover
20.45 Oz (0.580 kg)
21.59 Oz (0.610 kg)
Weight
Reliability Specifications
Parameter
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
50
Typ.
Max.
Units
kHours
MTBF
Safety Standards
Vibration
UL 1950, EN 60950 (except 5 VOUT model)
10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
www.micropowerdirect.com