DELTA P/N : MPT1030-H1 Series
Mechanical dimensions
Unit : mm
R24 / R33 / R36 / R47
R56 / R68
1R0 / 1R5 / 2R2 / 3R3
4R7 / 8R2 / 100 / 150
220
A’
A
B
11.15 ± 0.35
10.85 ± 0.35
10 0 ± 0.3
2.8 ± 0.2
2.0 ± 0.5
2.5 ± 0.1
3.0 ± 0.5
5.0 ± 0.2
0~0.15
4.1
C
C’
D
D’
E
F
G
H
5.4
13.6
Electrical Characteristics
Lo @0A
DCR
Part No.
(uH)
Ir(Adc)
Isat(Adc)
(mΩ)
± 20%
TYP.
1.1
MAX
1.27
1.6
MPT1030-R24H1
MPT1030-R33H1
MPT1030-R36H1
MPT1030-R47H1
MPT1030-R56H1
MPT1030-R68H1
MPT1030-1R0H1
MPT1030-1R5H1
MPT1030-2R2H1
MPT1030-3R3H1
MPT1030-4R7H1
MPT1030-8R2H1
MPT1030-100H1
MPT1030-150H1
MPT1030-220H1
NOTES:
0.24
0.33
0.36
0.47
0.56
0.68
1.0
30.0
23.0
23.0
23.0
22.0
21.0
15.0
13.5
13.0
9.0
50.0
32.0
28.0
26.0
24.0
23.0
21.0
20.0
16.0
14.0
13.0
8.5
1.3
1.3
1.6
2.1
2.5
2.4
3.0
2.9
3.4
5.3
6.0
1.5
6.5
7.5
2.2
8.0
9.0
3.3
14.5
20.5
35.0
50.0
59.0
90.0
16.0
22.5
45.0
55.0
65.0
99.0
4.7
7.0
8.2
5.0
10.0
15.0
22.0
5.0
7.5
4.0
6.0
3.0
5.0
(1) All test data is referenced to 25℃ ambient.
(2) Ir is the DC current which cause the surface temperature of the part increse approximate 40℃
(3) Isat is the DC current which cause the inductance drop approximate 30% of Lo.
(4) Operating temperature range -55℃ to 125℃. (The part temperature should be keepped under 125℃
when the worse operating condition apply on it. Circuit design, component placement,
PWB tracesize and thickness, airflow and other cooling provision may affect the part temperature.
Part temperature should be verified in the end application.)
(5) The rated current is depended on Ir and Isat which one is lower.