Series
MPM-04E
Low Cost, Board Mount 4W
Single And Dual Output
AC/DC Power Supplies
Key Features:
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• 4W Output Power
Input
Parameter
• Miniature Size
Conditions
Min.
85
120
47
Typ.
Max.
264
370
440
Units
VAC
VDC
Hz
• EN 60950 Approved (UL)
• ErP Directive Compliant
• Universal 85-264 VAC Input
• Meets IEC Safety Class II
• Single and Dual Outputs
• Meets EN 55022 B
Input Voltage Range
Input Frequency
Input Current
See Model Selection Guide
115 VAC
230 VAC
15.0
25.0
Inrush Current
A Pk
EMI
Meets CISPR Pub. 22/FCC Class B
Output
Parameter
Conditions Min. Typ.
Max.
Units
Output Voltage
Output Current
See Model Selection Guide
See Model Selection Guide
Output Voltage Accuracy
Line Regulation, See Note 3
Load Regulation, Single Output
Load Regulation, Single Output
Load Regulation, Dual Output, See Note 4
Ripple/Noise (20 MHz)
Ripple/Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection, See Note 4
Overload Protection, See Note 5
General
See Note 2
1.0
0.5
1.0
0.5
0.5
100
0.8
20
0.01
120
1.0
1.0
1.5
1.0
1.0
150
1.0
%
%
%
%
%
VIN = Min to Max
3.3V output, IO = 0% to 100%
5V to 24V output, IO = 0% to 100%
IO = 10% to 100%
Single 3.3V & 5V Outputs
All Other Models
mVP-P
%VP-P of VO
mSec
%/°C
% of VO
115 VAC
0.02
Zener Diode Clamp
Continuous (Autorecovery)
105
% of IO
Parameter
Isolation Voltage
Isolation Resistance
EMI/RFI
Conditions
Min.
Typ.
Max.
Units
VAC
M⍀
Input to Output 3,000
500 VDC
Conducted
100
EN 55022 Level B
EN 61000-4-2 Level B
EN 61000-4-3 Level A
EN 61000-4-4 Level B
EN 61000-4-5 Level B
EN 61000-4-6 Level B
EN 61000-4-8 Level A
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Conducted Disturbances
Power Frequency Field Immunity
Voltage Dip, Interruption & Variation
EMC Compliance
EN 61000-4-11 Level B/C
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
130
kHz
Conditions
Min.
-25
-40
Typ.
+25
Max.
+60
+85
Units
°C
°C
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Ambient
Free Air Convection (See Derating Curve)
RH, Non-condensing 95
Humidity
Physical
%
Case Size
Case Material
Weight
Reliability Specifications
Parameter
1.44 x 1.06 x 0.67 Inches (36.5 x 27.0 x 17.1 mm)
Non-Conductive Plastic & Fiberglass (UL94-V0)
0.91 Oz (26g)
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
330
kHours
Safety Standards
Safety Class
ECO Design
EN 60950
IEC 60536 Class II
ErP Directive 2009/125/EC
www.micropowerdirect.com