NOTES:
1.
MMSDX-XX-XXX-X-XX.XX-X-X-XXX
REVISION AD
REPRESENTS A CRITICAL DIMENSION.
FEP CABLE OPTION
2. BURR ALLOWANCE: .003[.08] MAX.
-T: FEP INSULATION
(LEAVE BLANK FOR STANDARD
PVC INSULATION)
OPTION
SINGLE
3. PARTS TO BE MOLDED TO POSITION.
DO NOT
SCALE FROM
THIS PRINT
4. MINIMUM PIN PULLOUT FORCE: 4.000LB[17.79N]
5. CONTACT MUST BE INSERTED UNTIL RETENTION
FEATURE LOCKS INTO PLACE.
-M: METAL LATCH (USE IPD1-XX-D-X-M)
No OF POSITIONS
-02 THRU -25
(PER ROW)
WIRE GAUGE (AWG)
PVC: -20, -22, -24, -26, -28, -30
FEP: -20,-24-28-30
(LEAVE BLANK FOR PLASTIC)
6. ALL FINISHED GOODS ARE TO BE ELECTRICAL TESTED INCLUDING HI-POT TEST
@ 1000 VOLTS DC. AFTER FINAL ELECTRICAL TEST, LABEL EACH ASSEMBLY
WITH 1 LABEL-ET.
DOUBLE
-LUS: PLASTIC LATCH UP, STRAIGHT
-LDS: PLASTIC LATCH DOWN, STRAIGHT
-LUX: PLASTIC LATCH UP, CROSSED
-LDX: PLASTIC LATCH DOWN, CROSSED
-MUS: METAL LATCH UP, STRAIGHT
-MDS: METAL LATCH DOWN, STRAIGHT
-MUX: METAL LATCH UP, CROSSED
-MDX: METAL LATCH DOWN, CROSSED
AD
7. TINNED COPPER WIRE IS ROHS COMPLIANT.
8. PARTS ARE TO BE LAYER PACKAGED.
9. MINIMUM METAL LATCH RETENTION FORCE: 1.000LB[4.45N]
10. REFER TO CRIMP SPECIFICATIONS PRINT FOR CRIMP AND STRIP
DIMENSIONS, TOLERANCES, AND TOOLING.
COLOR CODE
C (SEE TABLE 3, SHEET 3)
(LEAVE BLANK FOR STANDARD
BLACK CABLE)
11. FOR LENGTHS LESS THAN 12 IN, TOLERANCE SHALL
BE ±.125[3.18]. FOR OTHER LENGTHS, TOLERANCES SHALL BE ±2%.
(NOT AVAILABLE WITH FEP OPTION)
PLATING SPECIFICATION
POLARIZATION OPTION
(-P, -K, OR -G OPTION IS REQUIRED.)
-P: POLARIZATION (SEE FIG 3, SHEET 2)
(NOT AVAILABLE WITH -LUS, -LDS, -LUX, -K, -G OPTIONS)
-K: KEYED POLARIZATION
-F: FLASH SELECTIVE (USE C-179-XX-F)
-L: LIGHT SELECTIVE (USE C-179-XX-L)
-S: SELECTIVE (USE C-179-XX-S)
(No OF POS x .100[2.54])
+ .055[1.40] REF
05
01
ASSEMBLED LENGTH
(USE IPD1-XX-D-K) (SEE FIG 4, SHEET 2)
(NOT AVAILABLE WITH -P, -G OPTIONS)
-G: GUIDE POST
SPECIFY IN INCHES [USE DWC-XX-XX]
(SINGLE END: 03.00 INCH MINIMUM,
DOUBLE END: 03.25 INCH MINIMUM)
.353 8.97
REF
.250 6.35
REF
(USE IPD1-XX-D-GP) (SEE FIG 6, SHEET 3)
(NOT AVAILABLE WITH -LDS, -LUX, -P, -K OPTIONS)
END OPTION
-S: SINGLE END
-D: DOUBLE END
(LEAVE BLANK FOR NO POLARIZATION;
AVAILABLE TO EXISTING CUSTOMERS ONLY)
10
06
(MUST CHOOSE FROM
LUS, LDS, LUX, LDX, MUS,
MDS, MUX, OR MDX)
IPD1-XX-D
.100 2.54
REF
"A"
.505 12.83
REF
.285 7.24
REF
C
DWLX-02-XXXX-D-XX.XX-XX-XX
XX.XX
(SEE NOTE 11)
C
XX.XX
(SEE NOTE 11)
DWLX-02-XXXX-S-XX.XX-XX-XX
FIG 1
MMSD-05-22-X-XX.XX-S SHOWN
SECTION "A"-"A"
"A"
FIG. 2
MMSD-05-22-X-XX.XX-D SHOWN
PROPRIETARY NOTE
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DECIMALS
ANGLES
2
.XX: .01 [.3]
520 PARK EAST BLVD, NEW ALBANY, IN 47150
.XXX: .005 [.13]
PHONE: 812-944-6733
FAX: 812-948-5047
code 55322
.XXXX: .0020 [.051]
e-Mail info@SAMTEC.com
MATERIAL:
DO NOT SCALE DRAWING
SHEET SCALE: 1:0.666667 DESCRIPTION:
.100[2.54] SOCKET DISCRETE CABLE ASSEMBLY
HOUSING: NYLON 66, COLOR: WHITE
CONTACT: PHOS BRONZE
DWG. NO.
CABLE; INSULATION: SEE CALLOUT
WIRE: TINNED COPPER
MMSDX-XX-XXX-X-XX.XX-X-X-XXX
LATCH: NICKEL-PLATED BeCu, #25, 1/2 HT
F:\DWG\MISC\MKTG\MMSDX-XX-XXX-X-XX.XX-X-X-XXX-MKT.SLDDRW
BY:
DEAN P
07/16/2004 SHEET 1 OF 3