MMU 0102, MMA 0204, MMB 0207 - Professional
www.vishay.com
Vishay Beyschlag
Professional Thin Film MELF Resistors
FEATURES
• IECQ-CECC
EN 140401-803
approved
according
to
• AEC-Q200 qualified
• Advanced metal film technology
• Excellent overall stability: exceeds class 0.25
• Best in class pulse load capability
• Intrinsic sulfur resistance
• Material categorization: for definitions of
compliance please see www.vishay.com/doc?99912
MMU 0102, MMA 0204, and MMB 0207 professional thin
film MELF resistors are the perfect choice for most fields of
modern professional electronics where reliability and
stability is of major concern. The typical applications in the
fields of automotive, telecommunication and medical
equipment reflect the outstanding level of proven reliability.
APPLICATIONS
• Automotive
• Telecommunication
• Industrial
• Medical equipment
TECHNICAL SPECIFICATIONS
DESCRIPTION
MMU 0102
MMA 0204
0204
MMB 0207
0207
DIN size
0102
Metric size code
Resistance range
Resistance tolerance
RC2211M
RC3715M
RC6123M
0.22 Ω to 2.21 MΩ; 0 Ω
5 %; 2 %; 1 %; 0.5 %
0.22 Ω to 10 MΩ; 0 Ω
5 %; 1 %; 0.5 %
0.1 Ω to 15 MΩ; 0 Ω
5 %; 2 %; 1 %; 0.5 %
100 ppm/K; 50 ppm/K;
25 ppm/K
Temperature coefficient
50 ppm/K; 25 ppm/K
(1)
Rated dissipation, P70
0.3 W
150 V
0.4 W
200 V
1.0 W
350 V
Operating voltage, Umax. ACRMS/DC
Permissible film temperature, ϑF max.
Operating temperature range (1)
(1)
155 °C
-55 °C to 155 °C
Permissible voltage against ambient (insulation):
1 min, Uins
200 V
300 V
500 V
Failure rate: FITobserved
≤ 0.05 x 10−9/h
Note
(1)
Please refer to APPLICATION INFORMATION below
APPLICATION INFORMATION
When the resistor dissipates power, a temperature rise above the ambient temperature occurs, dependent on the thermal
resistance of the assembled resistor together with the printed circuit board. The rated dissipation applies only if the permitted
film temperature is not exceeded.
These resistors do not feature a limited lifetime when operated within the permissible limits. However, resistance value drift
increasing over operating time may result in exceeding a limit acceptable to the specific application, thereby establishing a
functional lifetime.
Revision: 24-Aug-2021
Document Number: 28713
1
For technical questions, contact: melf@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000