MLCC Medical Applications – MM Series
General Specifications
The AVX MM series is a multi-layer ceramic capacitor designed for use in medical applications other than
implantable/life support. These components have the design & change control expected for medical devices
and also offer enhanced LAT including reliability testing and 100% inspection.
APPLICATIONS
Implantable, Non-Life Supporting Medical Devices
• e.g. implanted temporary cardiac monitor, insulin pumps
External, Life Supporting Medical Devices
• e.g. heart pump external controller
External Devices
• e.g. patient monitoring, diagnostic equipment
HOW TO ORDER
MM02
Z
A
100
J
G
T
3
A
Capacitance
Tolerance
Size
Rated
Dielectric
Code
A = NP0 (C0G)
C = X7R
Capacitance
Code (In pF)
(2 significant
digits + number
of zeros)
for values <10pF:
letter R denotes
decimal point.
Example:
68pF = 680
8.2pF = 8R2
Failure Rate
C = Standard
Range
Termination
Finish
Packaging
Special
Code
2 = 7" Reel
MM02 = 0402 Voltage
MM03 = 0603 Z = 10V
MM05 = 0805 Y = 16V
MM06 = 1206 3 = 25V
MM10 = 1210 5 = 50V
MM08 = 1808 1 = 100V
MM12 = 1812 2 = 200V
MM20 = 2220 V = 250V
7 = 500V
4 = 13" Reel A = Standard
B = ±0.1pF
T =Plated Ni & Sn
(NP0 only)
C = ±0.25pF
D = ±0.5pF
F = ±1% (≥10pF)
G = ±2% (≥10pF)
J = ±5%
K = ±10%
M = ±20%
Contact AVX
for others
Contact AVX
for others
Z =Flexiterm
(X7R only)
COMMERCIAL VS MM SERIES PROCESS COMPARISON
Commercial
MM Series
Standard part numbers; no restriction on
Specific series part number, used to control supply
of product
Administrative
who purchases these parts
Minimum ceramic thickness of 0.020" on all
X7R product
Design
Minimum ceramic thickness of 0.022" (0.56mm)
Side & end margins = 0.004" min
Cover layers = 0.003" min
Dicing
Side & end margins = 0.003" min
Lot Qualification Destructive
Physical Analysis (DPA)
As per EIA RS469
Increased sample plan – stricter criteria
Visual/Cosmetic Quality
Application Robustness
Standard process and inspection
100% inspection
Standard sampling for accelerated wave
solder on X7R dielectrics
Increased sampling for accelerated wave solder on
X7R and NP0 followed by lot by lot reliability testing
AVX will qualify and notify customers before
making any change to the following materials or
processes:
• Dielectric formulation, type, or supplier
• Metal formulation, type, or supplier
• Termination material formulation, type, or supplier
• Manufacturing equipment type
Required to inform customer of changes in:
• form
• fit
Design/Change Control
• function
• Quality testing regime including sample size and
accept/ reject criteria