FEATURES
► Smallest Encapsulated 40W Converter!
► Package Size 2.0”x 1.0”x 0.4”
► Ultra-wide 4:1 lnput Range
► Excellent Efficiency up to 90%
► Operating Temp. Range -40°C to +80°C
► Over-temperature Protection
► I/O-isolation Voltage 1500VDC
► Remote On/Off Control
► Shielded Metal Case with Isolated Baseplate
► 3 Years Product Warranty
PRODUCT OVERVIEW
The MKWI40 series is the latest generation of high performance DC-DC converter modules setting a new standard concerning power density. The product
offers fully 40W in an encapsulated, shielded metal package with dimensions of just 2.0”x1.0”x0.4”. All models provide ultra-wide 4:1 input voltage range
and precisely regulated output voltages.
Advanced circuit topology provides a very high efficiency up to 90% which allows an operating temperature range of -40°C to +80°C. Further features
include remote On/Off, trimmable output voltage, under-voltage lockout as well as overload and over-temperature protection.
Typical applications for these converters are battery operated equipment, instrumentation, distributed power architectures in communication and industrial
electronics and many other space critical applications.
Model Selection Guide
Model
Input
Voltage
(Range)
VDC
Output
Output Current
Input Current
Reflected
Ripple
Over
Max. capacitive
Load
Efficiency
Number
Voltage
Voltage
(typ.)
@Max. Load @No Load
Current
mA (typ.)
Protection
Max.
mA
Min.
@Max. Load
VDC
3.3
5
mA
mA(typ.)
1240
1850
1870
1870
1870
1890
1890
620
mA(typ.)
90
VDC
3.9
6.2
15
μF
%
89
90
89
89
89
88
88
89
90
90
90
89
88
88
MKWI40-24S033
MKWI40-24S05
MKWI40-24S12
MKWI40-24S15
MKWI40-24S24
MKWI40-24D12
MKWI40-24D15
MKWI40-48S033
MKWI40-48S05
MKWI40-48S12
MKWI40-48S15
MKWI40-48S24
MKWI40-48D12
MKWI40-48D15
8000
8000
3330
2670
1670
±1670
±1330
8000
8000
3330
2670
1670
±1670
±1330
0
21000
13600
2400
1500
600
0
90
12
0
95
24
(9 ~ 36)
15
0
105
115
65
30
18
24
0
±145
±110
0
30
±12
±15
3.3
5
±15
±18
3.9
6.2
15
1200#
750#
21000
13600
2400
1500
600
65
55
0
930
55
12
0
930
60
48
(18 ~ 75)
15
0
930
65
20
18
24
0
940
75
30
±12
±15
±145
±110
950
45
±15
±18
1200#
750#
950
45
# For each output
Input Specifications
Parameter
Model
Min.
Typ.
---
Max.
50
Unit
-0.7
-0.7
---
24V Input Models
48V Input Models
24V Input Models
48V Input Models
24V Input Models
48V Input Models
Input Surge Voltage (100ms. max.)
Start-Up Threshold Voltage
---
100
9
---
VDC
---
---
18
---
8.3
16.5
---
Under Voltage Lockout
Input Polarity Protection
---
---
None
---
Power Up
Remote On/Off
---
---
30
30
ms
ms
Start Up Time
Nominal Vin and Constant Resistive Load
All Models
---
Internal Filter Type
LC Filter (for EN55022,Class A compliance see page 7)
Short Circuit Current
--- (Hiccup Mode 1.5 Hz typ.)
Total Power International, Inc
Toll Free: 877-646-0900